Current Injection
-
Product
NI-9203, 200 kS/s, ±20 mA, 8-Channel C Series Current Input Module
779516-01
Current Input Module
200 kS/s, ±20 mA, 8-Channel C Series Current Input Module - The NI‑9203 is intended for high-performance control and monitoring applications. It features programmable input ranges and variable connectivity options. To protect against signal transients, the NI‑9203 includes a channel‑to‑earth ground double‑isolation barrier (250 Vrms isolation) for safety and noise immunity.
-
Product
Rogowski AC Current Probe,30 MHz, 300 A
N7042A
High Current Probe
The Keysight N7042A Rogowski coil current probe measures AC currents up to 300 A, with bandwidth ranging from 9.2 Hz to 30 MHz. The probe has a thin, lightweight, flexible, and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult-to-reach parts and confined spaces of a circuit under test. It can also measure large AC current without an increase in transducer size.
-
Product
N2782B AC / DC Current Probe, 50 MHz, 30 Arms
N2782B
High Current Probe
The N2782B current probe is an accurate and reliable solution for measuring AC and DC currents. Using a hybrid technology that includes a Hall effect sensor and an AC current transformer, the probe provides accurate measurement of DC or AC currents up to 30 Arms continuous.
-
Product
Standard - 1.44 (41.00 - 4.50 (128.00) High Current Probe
HCP-13H
High Current Probe
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Rogowski AC Current Probe, 23 MHz, 3000 A
N7040A
High Current Probe
The Keysight N7040A Rogowski coil current probe is designed for measuring AC currents up to 3,000 A with the bandwidth ranging from 3 Hz to 23 MHz. The probe is easy to use because it has a thin, lightweight, flexible and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult to reach parts and confined spaces of a circuit under test. It can also measure large AC current without increase in transducer size.
-
Product
NI-9208, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module
785041-01
Current Input Module
500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.
-
Product
NI-9253, 50 kS/s/ch, ±20 mA, 24-Bit, 8-Channel C Series Current Input Module
785989-01
Current Input Module
50 kS/s/ch, ±20 mA, 24-Bit, 8-Channel C Series Current Input Module - The NI-9253 is an 8-channel analog input module for ComapctDAQ and CompactRIO systems. Each channel provides a ±20 mA input range and 24 bits of resolution at a 50 kS/s sample rate. The NI-9253 has several diagnostic features to ensure your system is operating nominally at all times with open channel detection, power supply detection, and configurable thresholds. The NI-9253 has eight LEDs to indicate the status of each channel and the power supply so that a user in the field can easily validate that the system is operating normally. The NI-9253 also features a number of programmable hardware filters. By choosing the specific Butterworth and comb filters for your application, you can significantly reduce the noise in your system.
-
Product
Sample Injection System
ASXPRESS Plus
-
A sample introduction system such as the ASXpress® Plus from Teledyne LABS reduces the time required for autosampler movement, sample uptake, stabilization, and rinse operations, thereby reducing sample run times significantly. The result: more sample throughput in less time. The accessory’s design allows multiple functions to occur simultaneously. A highspeed vacuum pump loads the sample and flushes the sample uptake path substantially faster than a conventional peristaltic pump.When coupled to a compatible autosampler, the ASXPRESS Plus Rapid Sample Introduction Accessory minimizes times for sample delivery, stabilization, and washout with ICP-AES or ICP-MS. The result is increased sample throughput by up to 5 times or more. In addition, the ASXPRESS PLUS reduces costs from argon, power, ICP-AES / ICP-MS components, and system maintenance.
-
Product
NI-9266, 8-Channel C Series Current Output Module
785047-01
Current Output Module
8-Channel C Series Current Output Module - The NI‑9266 is ideal for interfacing and controlling industrial current-driven actuators. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9266 includes channel‑to‑earth ground isolation for safety and noise immunity.
-
Product
Indirect Sequential Injection
-
The ECU is designed to exploit the chemical-physical characteristics of the gas fuel used in Otto engines while maintaining the level of emissions of the exhaust gas according to the original standard car.The connector used in Air 48 is automotive type 48- Poles . The connection to the engine signals , offers exceptional qualities of connective security and protection against water infiltration .
-
Product
C Series Voltage And Current Input Module
Current Input Module
The C Series Voltage and Current Input Module features up to 16 input channels with built-in noise rejection. You can use this module to combine the two most common inputs to reduce the overall number of modules you need in your measurement system.The C Series Voltage and Current Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
Product
CP400X, 400 MHz, ±60 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
784254-01
High Current Probe
The CP400X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 2 meters in length. The CP400X attaches to BNC connections on both the signal input and instrument sides.
-
Product
NI-9253, 50 kS/s/ch, ±20 mA, 24-Bit, 8-Channel C Series Current Input Module
785989-02
Current Input Module
50 kS/s/ch, ±20 mA, 24-Bit, 8-Channel C Series Current Input Module - The NI-9253 is an 8-channel analog input module for ComapctDAQ and CompactRIO systems. Each channel provides a ±20 mA input range and 24 bits of resolution at a 50 kS/s sample rate. The NI-9253 has several diagnostic features to ensure your system is operating nominally at all times with open channel detection, power supply detection, and configurable thresholds. The NI-9253 has eight LEDs to indicate the status of each channel and the power supply so that a user in the field can easily validate that the system is operating normally. The NI-9253 also features a number of programmable hardware filters. By choosing the specific Butterworth and comb filters for your application, you can significantly reduce the noise in your system.
-
Product
Fuel Injection Tester
FIT13A
-
This basic fuel injection tester includes large and small Schrader adapters, M6-1.00 O-ring adapter, and tee manifold. Includes everything necessary to test the following systems: American Motors; Bosch AFC, MPC European and Japanese (except CIS- use our FIT447); Chrysler Corporation; Ford Motor Company; GM (except TBI- use our FIT446); Japanese fuel injection systems; a The 2-1/2" gauge has a dual scale dial with ranges from 0-100psi and 0-7 bar.
-
Product
Standard - 1.44 (41.00) - 4.50 (128.00) High Current Probe
HCP-13P
High Current Probe
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Secondary Injection Test Set
PTE-100-C
-
The PTE-100-C is a portable Universal test equipment for testing electromechanical, electronic, and digital relays. The equipment can output a variable current up to 250A, a variable AC Voltage up to 250V, a variable DC Voltage up to 350V. Also the unit incorporates a variable stabilized auxiliary DC Voltage supply up to 250V and a fixed AC Voltage output up to 110V, which can be variable with the PTE-FCF option.
-
Product
Injection Transformer
J2100A
-
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
Product
Primary Injection Test System
-
HAOMAI Electric Test Equipment Co., Ltd.
Primary injection testing is suitable for testing over-current trip relays attached to a circuit breaker.
-
Product
Current Sources
-
Innovar Current Sources are the standard in the circuit breaker industry. Our Current Sources supply regulated current from 1 amp to 100,000 amps with incredible accuracy, along with providing a full set of features that is unmatched by any other Current Source in the market.
-
Product
Current Dataloggers
-
With our selection of current data loggers, you can meet requirements that include the single/split phase, three-phase, neutral, ground current and machine load monitoring. You can also utilize our current loggers for fault current detection, leak identification, and load profiling. We have compact models constructed to be weatherproof. Choose from stand-alone, handheld and clamp-on configurations. Our current data loggers are used in a broad scope of applications, trusted by technicians, electricians and engineers.
-
Product
Current Transformer
ST-30RCT
-
Standard Electric Works Co., Ltd
● Primary Current Rating (Amp) : 1600~4000
-
Product
Mixed Injection System Liquid Vaporizers
MI-1000/MV-1000
-
This mixed injection system can rapidly vaporize a wide variety of liquid sources by using the gas-liquid mixture vaporization method. This method allows for the stable vaporization of high boiling point liquids.
-
Product
Current Transformer
ST-60CT
-
Standard Electric Works Co., Ltd
● 400/5A - 800/5A● 7.5-10V A● Class 1● Insulation 600V
-
Product
Fuel Injection Tester
FIT13APB
-
This basic fuel injection tester includes large and small Schrader adapters, M6-1.00 O-ring adapter, and tee manifoldIncludes everything necessary to test the following systems: American Motors; Bosch AFC, MPC European and Japanese (except CIS- use our FIT447); Chrysler Corporation; Ford Motor Company; GM (except TBI- use our FIT446)
-
Product
sbRIO-9265, Non-Enclosed, 4-Channel C Series Current Output Module
780921-01
Current Input Module
Non-Enclosed, 4-Channel C Series Current Output Module - The sbRIO‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The sbRIO‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity. Non-enclosed modules are designed for OEM applications.
-
Product
Single Phase DC Injection Set Kit
PDC120A/PDC200A
-
PDC120A/PDC200A Single Phase DC current injection set kit is portable test set which could generate DC current for the various testings in railway transportation, HVDC converting stations, etc.
-
Product
Current Measurement
-
Measurements International Ltd.
No Stabilization Period, No Power Coefficient, No Temperature Coefficient, DC and AC Operation, 3000 A Max Current DC.
-
Product
Current Booster
BUX
-
The current boosters allow performing tests up to 2000A, 3000A and 5000A. The option is made of a module, which incorporates a power transformer, which generates a low-voltage, high current output and a metering CT, which measures the output current and sends the metering to eKAM.
-
Product
Current Amplifiers
-
In order to achieve an extremely low noise performance very high gains were chosen, while nevertheless minimizing the associated bandwidth reduction.Thus, as a result of our sophisticated development efforts we can offer a professional "High-End" Current Amplifier line. The noise performance of our products surpasses by far that of conventionally designed OpAmp current-to-voltage converters at the corresponding bandwidth.
-
Product
Fault Injection and White-Box Testing
VectorCAST/Probe
-
VectorCAST/Probe is integrated with the full family of VectorCAST tools allowing probes to be inserted during Unit, Integration, or System Testing. The probe insertions are controlled by the same technology that controls our code coverage instrumentation, which ensures that the probes function correctly regardless of the compiler, target processor, or run-time environment.