Current Transducers
-
Product
Logger version 2-D electro-magnetic current meter
INFINITY-EM AEM-USB
-
Infinity EM is an autonomously deployable EM (electro-magnetic) current meter with a data logger. Due to the principle, the instrument provides high accurate 2-D current measurements in even low scatter fields, where ADVs (Acoustic Doppler Velocimeter) has difficulties. The measurement range is wide from 0 to ± 500 cm s-1. The instrument design is compact (1.0kg in air). Infinity EM allows for current velocity measurements virtually anywhere.
-
Product
30A, 50 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CP030B
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
DC Pulse Current Capacitor
-
Both series can be customized as Low Voltage High Capacitance High Current Capacitors.We can customize Snubber Capacitor as Box type and support other parameters.For 250Vac~900Vac / 400Vdc~1,350Vdc and with higher Current requirement, please refer to our AC/DC Power Capacitors.Different applications can have very different capacitor electrical and mechanical profile requirements.Please feel free to send your application details for a suggestion and quotation.
-
Product
Compact Eddy Current Sensor System
eddyNCDT 3005
-
Compact and robust design. - Temperature compensation up to 180C. High precision measurement accuracy. High frequency response. Sensor for ferro- and non-ferromagnetic targets. Easy to use (plug & play). Perfect for machine integration.
-
Product
30 Amps, 50 MHz BW Current Probe - AC/DC , 50 Amp Peak Pulse
CP030
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
Calibrator, Calibrated, Current, 185 mm, 78 mm, 38 mm, ± (0.25% FS +1 digit), ± (0.5%FS + 1 digit)
72-6694 CAL
-
The 72-6694 CAL from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
Product
Three Phase Secondary Current Injection Test Set
TEST-330B
-
Beijing GFUVE Electronics Co.,Ltd.
Three phase secondary current injection test set is testing relay set, protective device, instruments, output ac dc current and voltage source, embedded Window XP system.
-
Product
Handheld 1-D electro-magnetic current meter for rivers
AEM1-DA
-
AEM1-DA is a 1-D electro-magnetic (EM) current meter for the flow measurements in rivers, streams and various waterways. The measurement range is 0 to 5m s-1. The EM sensor can accurately measure water speeds at a shallow depth of 3cm. The display unit has a 2MB flash memory so that the data are saved with calendar information (up to 255 station data). In comparison with conventional propeller-type current meter, AEM1-DA is robust and extremely easy to be operated and maintained.
-
Product
Precision Pressure Transducers
-
Precision and digital pressure transducers, somemtimes known as precision pressure sensors, convert pressure into an analog or digital signal proportional to the pressure being sensed. A precision pressure transducer (also referred to as a pressure transmitter) are used to monitor and or control sensitive pressure processes. They can also be used as high accuracy transfer standards or as a factory working standard for testing or calibrating a variety of pressure measuring instruments. With an accuracy as high as 0.008 % of reading, these pressure transducers can be found in laboratories or in production environments where a high degree of precision and accuracy are required. Each transducer is calibrated in Mensor's 17025, A2LA certified laboratory.
-
Product
Frequency to Current Converter
DAT4540R
-
The Frequency to Current converter DAT4540R is a signal conditioning din rail mount converter which converts a pulse input to an analog output equal to the set range which is selectable from 0.1 Hz up to 20 KHz. The DAT4540R also provides 2 relay outputs and a transistor output. The input can be from a Tacho, TTL, PNP transistor or from any Namur standard. The DAT4540R provides a Voltage or Current output that is isolated from the power supply and input.
-
Product
Eddy Current Dynamometer
EC Series
-
Specifically designed for small displacement diesel engines, the Eddy Current (EC-Series) engine dynamometer features in-line eddy current absorption units in a robust, compact frame. The air-cooled eddy current absorbers eliminate the need for an expensive water recirculation system and most engines being tested can be cooled with a standard closed-circuit radiator system. This compact air-cooled design results in a minimal environmental impact and the ability to be easily relocated with no need for a permanent installation. When combined with PowerNet LT, our fully automated dynamometer control system, all of your testing needs can be performed at the touch of a button.
-
Product
Electromechanical Calibration for Transducer
ELCS-500
-
Jinan Testing Equipment IE Corporation
The electromechanical calibration system is specially designed for the calibration of transducers. The calibration for transducer can calibrate the load cell accuracy within +/- 0.5%.
-
Product
PXI/PXIe Wide Current Range Matrix Module, 6x4, 2-Pole, X & Y Loop-thru
42-514-002
Matrix Switch Module
The 40-514-002 (PXI) and 42-514-002 (PXIe) are low density matrices in 6x4 2-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
Handheld 2-D EM current meter with temperature and depth sensor
AEM213-D
-
AEM213-D electro-magnetic current meter with a display unit can provide the 2-D current speeds in real time. The instrument has a depth and a temperature sensor as well as the current sensor, enabling reliable current measurements at the desired depths. The compact and light-weight unit is easily portable, allowing you to use the instrument in a variety of situations.
-
Product
Analog AC Leakage Current Clamp Tester
MCL-350
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*High accuracy analog display with strong taut band meter.*3 years long battery life.*Meter lock function and data output for recorder.*Filter rejection for high frequency noise
-
Product
PXI/PXIe Wide Current Range Matrix Module, 6x4, 2-Pole, X & Y Loop-thru
40-514-002
Matrix Switch Module
The 40-514-002 (PXI) and 42-514-002 (PXIe) are low density matrices in 6x4 2-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
Current Probes
-
Teledyne LeCroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combination of Hall effect and transformer technology, Teledyne LeCroy current probes are ideal for making accurate AC, DC, and impulse current measurements.
-
Product
Transducers
-
CRYSOUND offers an impressive array of sensor products, including measurement microphones, preamplifiers, artificial ear coupling cavities, and artificial mouth sound sources. These diverse products enable us to meet the specific needs of our clients with precision and innovation.
-
Product
Low TCR High Power Current Sensing Resistors, Wide Terminal Type
-
Panasonic Industrial Devices Sales Company of America
Panasonic's ERJ-D1 and ERJ-D2 Series, Low TCR High Power Current Sensing Chip Resistors, achieve high power and low TCR (±100×10–6/°C) using a wide terminal electrode structure and original materials.These Resistors are suitable for small size/high power current detection and their low TCR enables high accuracy of current detection. The ERJ-D1 Series features higher rated power at 2W in a 1020 case size while the ERJ-D2 Series features 1W in a 0612 case size. These Resistors are AEC-Q200 Compliant and offer IEC 60115-8, JIS C 5201-8 and EIAJ RC-2134B Reference Standards ensuring optimal quality and reliability.
-
Product
Inrush Current Generators for Zno Production Line
-
Shanghai Guantu Technology Co., Ltd.
Inrush Current Generator Standard: IEC61008, IEC61009, I61051/61643, ANSI C62.31, C62.33, C62.35, TU K20, K21, K44, K45, UL943Inrush Current Generator Features1. LCD screen display, built-in computer control, man-machine dialogue, easy to operate.2. Program-controlled high-voltage power supply, high voltage stability and precision3. Imported non-inductive high-power resistors are used to ensure the consistency of surge waveforms4. The main switch adopts electronic switch discharge mode, and the output polarity is automatically switched
-
Product
Test and Measurement Grade Vacuum Pressure Transducer
P897V
-
The P897V is designed for a wide variety of pressure measurements where high resistance to vibration and superior stability through temperature change is required. The zero and full-scale output calibrations are set by the potentiometer adjustments accessible from the top cover. The P897V is digitally compensated and corrected to provide high accuracy pressure measurement in a robust cylindrical form factor. Small vacuum pressures are accurately measured with full scale vacuum ranges as low as 2.22 InH2O.
-
Product
150 A, 5 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 6 Meter Cable
CP150-6M
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
Industrial Pressure Transducers
-
These industrial Baratron® capacitance manometers feature industrial enclosures and higher operating temperature ranges for industrial pressure measurement applications.
-
Product
PXI/PXIe Battery Simulator Module, 2-Channel, Simplified Current Sink, 750 V Isolation
43-752A-903
Battery Simulator
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 2-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
Product
Split type Pulse Current Sensor
CTF-05
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
High accurate AC pulse current sensor for power demand meter.
-
Product
16 SE Or 8 Diff. Input Channels, 4 Analog Current Output Channels, PCI Express
APCIE-3121-16-4C
-
Input range:?± 10 V, 0-10 V software programmable0-5 V, ± 5 V, 0-2 V, ± 2 V, 0-1 V, ± 1 V (gain)0-20 mA (option) ? software-programmable amplifier:PGA x1, x2, x5, x10 ? Conversion triggered through software,scan, timer, external event ? Onboard FIFO buffering for 256 analog values ? Data exchange through 16-bit I/Oor 32-bit memory (PCI DMA) ? Sequence RAM ? Overvoltage protection ? input filter: 160 kHz
-
Product
Profiling Current Meter and Wave
SeaGuardII DCP Wave
-
The SeaGuardII DCP Wave is a 600kHz Doppler Current Profiler able to measure directional wave parameters and currents from a bottom mounted installation.The Acoustic Wave software 5759 used by the DCPS implements unique features to improve the wave measurement accuracy by optimizing the signal to noise ratio.Maximum deployment depth is 40m in normal scatter conditions. The Profiling Current Meter and Waveis available as a self-recording instrument. It can be easily integrated into a real-time system offering reliable two-way communication.
-
Product
Clamp type AC Current Sensor/for Load Current Measurements(CT Series)
CT-80
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Big CT window*AC 1A~1800A*Current measurements of main cable
-
Product
Coaxial Transducers
-
Concentric point source transducers deliver full frequency range in correct phase alignment, with precise polar pattern and perfect clarity.
-
Product
30A, 100 MHz CURRENT PROBE, BNC, AC/DC, 30A rms, 50A Peak Pulse
T3CP30-100
-
30A, 100 MHz CURRENT PROBE, BNC, AC/DC, 30A rms, 50A Peak Pulse.





























