Product
3U Processor Board
CP39101
-
LinkedHope Intelligent Technologies Co.,Ltd.
CP39101 is a 3U CompactPCI 4-channel independent isolated serial communication board, designed for industrial communication applications, compliant with PICMG R3.0 2.1 specification.CP39101 adopts EXER 17D158 communication processor as the master control chip. Each of the on-board 4-channel serial port can be individually configured as RS232, RS485 or RS422, and in any mode, CP39101 can be operated properly in extended temperature ( -40℃ to +85℃ ) range.
-
Product
3 Port cPCI Card
GX3903
-
The GX3903 is a 3-port, cPCI asynchronous communications interface board supporting RS232 and RS422 levels. Optionally, the board can support RS485 signaling. Each port is configured at the time of order for RS232, RS422 or RS485 signaling. The default configuration is RS232. For RS232 mode, each port supports RTS, CTS, TXD, RXD, DCD, DRC, DSR, and RI signaling. The RS422 mode supports TXD, RXD, CTS, and RTS with each line operating differentially with a uni-directional drive.
-
Product
ANSI X3.28 Interface Board
Model 4804B-7
-
* F30145 firmware converts printable ASCII character strings into the ANSI X3.28 serial protocol.* User selectable single-ended RS-232 and differential RS-422/RS-485 serial signals.* Can be used to replace obsolete ICS 4814 Interfaces.* Connect to the rear panel with a GPIB Flat-ribbon cable or with a GPIB Connector/Address Switch Cable.* Runs on 5 Vdc regulated or 5.5 to 15 V unregulated power.
-
Product
RFID
HF (13.56 MHz)
-
BIS M uses the high frequency (HF) 13.56 MHz and supports the standard according to DIN ISO 15693 and 14443. Communication modules/gateways are used for the point-to-point or bus linking and are directly connected to a serial interface of a PC/a bus interface. The Subnet16 TM bus architecture supports a subnet of up to sixteen nodes via an RS485 interface.
-
Product
LVDT Signal Conditioner
NTC-6000
-
Quick and easy setup with front panel push buttons and LED indicatorsSelectable excitation frequency, analog outputs and bandwidthAutomatic excitation synchronization for multiple unit systemsSelf-diagnostics for LVDT failure, disconnect, or short circuitDigital communications via RS-485 2-wire multi-drop busHot swapability — setup can be saved and reloaded via RS-485 portCybersecurity lockout and tamper detectWorks with nearly any AC LVDT, RVDT, or LVRT half bridge
-
Product
PMC-BiFIFO
-
The parallel Input and Output channels are highly programmable and fully independent. The standard interface offers Data, Clock and Strobe. The 32 RS485 channels are programmable as input or output allowing for a variety of implementations. The programmable output rates and RS422/485 compatability will interface to a multitude of systems.
-
Product
2.4/5GHz Wi-Fi I/O Module With 6DI/RS-485
WISE-4250-S251
Wireless I/O Module
Equipped with 6 digital inputs and 1 RS-485 in a compact, high-density I/O designSupports both dry and wet contact input modes for broad sensor compatibilityFail Safe Value (FSV) ensures outputs default to a safe state during communication lossSupports IEEE 802.11ac (2.4GHz/5GHz) for stable and high-speed wireless connectivityEnsures secure data transmission with WPA3/TLS 1.3 encryption and X.509 certificate authenticationStores 10,000+ data points locally with SNTP/RTC time sync and Watchdog timer auto connection recoveryOffers comprehensive protocol support, including MQTT, Modbus/TCP, SNTP, TCP/IP, HTTPS, RESTful, UDP, and DHCP
-
Product
3-CH RTD Input Module
ND-6013
Data Acquisition Module
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.
-
Product
4 2/3 Digital Process Meter (1/32 DIN)
CS3-PR
-
CS3-PR Process Indicator has been designed with 0~10V and 4(0)~20mA high accuracy measurement.A compact body design for small equipment, laboratory instrument, and others.Also are available with relay output, analog output, RS485 Modbus RTU communication to cover a wide range of applications.
-
Product
RS232 / RS485 / RS422 / TTL Serial Repeaters & Hubs
-
CommFront offers a range of rugged, industrial-grade RS232 / RS485 / RS422 / TTL repeaters and hubs to meet serial communications' data distance needs by converting unbalanced signals to balanced ones, deploying repeaters to boost signal strength, and implementing hubs for star-configured connections, while still taking full advantage of cost-effective and readily-available copper wire.
-
Product
Remote I/O
-
ADAM remote I/O are categorized into 5 families: IoT/OPC UA Ethernet I/O, Modular I/O system, RS-485 I/O and Serial/USB Converters/Repeaters.
-
Product
4G Router
ICR-2413
Router
ICR-2400, EMEA, 2× Ethernet , 1× RS232, 1× RS485, Metal, Without Accessories
-
Product
Power Amplifier
MS 2011
-
Power Amplifier is used to amplify the RF signals from low power to 100 Watts of RF carrier power to 400 Watts Peak envelop power (single side band operation). Outputs are filtered. This system is controlled through microprocessor and it has RS485 interface.
-
Product
10 Digit Rate/Batch Counter (Analogue)
CS2-TM-Analogue
-
The CS2-TM Totalizer controller provide high accuracy measurement, display, control and communication (Modbus RTU mode) of 0~10V/4~20mA from flow meter or mV from Shunt for Amp-Hour.There are two display screen and 3 external control input (DI) in standard and the optional 4 Relay, 1 Analogue, 1 Pulse and RS485 port available. They are also support fantastic control function as like as N, R, C mode for totalizer and batch control.
-
Product
RS485 Mode SI-module With Optical Isolation
MX485-G
-
RS485 mode SI-module with optical isolation
-
Product
Modbus Data Acquisition
-
The Datexel range of Data Acquisition equipment includes Modbus RTU Masters and Slaves, Modbus Input, Modbus Output Modules, Modbus Isolation Modules and Modbus Repeaters. The range also includes converters (RS485, USB, RS232, RS422, TCP-IP). By combining these units with the DAT3000 and DAT10000 series a complete solution for your Data Acquisition can be found from Datexel. The DAT9550 is a remote Modbus display unit that can be programmed to accept data from Modbus slaves or masters such as a PLC or the DAT9000 range of Modbus controllers.
-
Product
Signal Processor Board
MS 1532
-
- Frequency coverage from 5 kHz to 30 MHz in 1-Hz steps- High dynamic range: +30 dBm 3rd-order intercept typical- Digital filtering provides 58 IFBWs from 56 Hz to 8.0 kHz with exceptional shape factors- AM, Synchronous AM, FM, CW, USB, LSB & ISB detection modes standard- Tunable notch filter- Fast, flexible scanning with 100 memory channels- Large readable LED displays & user-friendly controls- Noise blanking & pass band tuning- Internal switchable preamplifier & attenuator- Operator-selectable RS-232, RS-485, or- RS-422 remote control- Viretx 5 FPGA based design (Two virtex for image processing)- LPC2468 ARM 7 Processor based design- MIL1553B and RS485 Interface- Two High speed 14 bit ADC (125MSPS) for I & Q Sampling- Direct sampling 2-30MHz- Audio CODEC- Conduction Cooled Board
-
Product
Digital Pressure Meter
ZET 7012-A-VER.1
-
Digital pressure meter ZET 7012-A in BP4-1 casing is used for fast and simple absolute pressure measurements and measured values data transfer in digital format via RS-485 or 4-20 mA interface.
-
Product
Cable Assembly, Receiver, TriPaddle, 20", 2 9-Pin Female D-Subs, for RS-422/485
540041010101
Cable Assembly
Cable Assembly, Receiver, TriPaddle, 20", 2 9-Pin Female D-Subs
-
Product
Cable Assembly, Receiver, TriPaddle, 36", 2 9-Pin Female D-Subs, for RS-422/485
540041010201
Cable Assembly
Cable Assembly, Receiver, TriPaddle, 36", 2 9-Pin Female D-Subs
-
Product
4 Serial Communication Channels, Multi-Mode Programmable, Isolated
SC2
-
Module SC2 supports intelligent, full duplex, independent, multi-channels that can be individually software-configured for either RS-232C, RS-422, RS-485, RS-423 (w/data and/or clk bit inversion for MIL-STD-188C unbalanced interface support), or synchronous or asynchronous communications.
-
Product
Analog Controller Meters
-
Accuracy 0.05% F.S.±1digit Measuring six channel DCA/DCV/Pt-100/Thermocouple/etc... Programmable rate -1999 to 9999 digit Input channel number(1~6) can be modified Digit RS-485 interface function (optional) CE EMC certification
-
Product
RS232 / RS485 / RS422 To Fiber Optic Converters
-
Our rugged, industrial-grade, point-to-point RS232 / RS485 / RS422 serial to fiber optic converters work in pairs to extend serial signals (RS232, RS485, RS422, and TTL) over long distance. These point-to-point RS232 / RS485 / RS422 serial to fiber optic converters have been designed for harsh industrial environments and withstand a wide temperature of -40°F to 185°F (-40°C to 85°C), and they come with the options of multi-mode (extend distance up to 3 miles / 5km) and single-mode (extend distance up to 25 miles / 40 km), and ST, SC, and FC connectors.
-
Product
Digital Interface Boards
Model 4863 OEM
-
* 114514 Board has same digital capability as the 4863 described above with GPIB IO.* GPIB interface header includes GPIB address switch input signals.* Use with any IC GPIB Connector/Address Switch Assembly.* Uses 9-32 Vdc power.* 114515 Board has same digital capability as the 4863 described above with GPIB and Serial IO.* GPIB interface header includes GPIB address switch input signals.* Serial interface header includes RS-232 and RS-485 signals. Use the 114597 Serial Cable Kit to connect the serial signals to your rear panel* Use with any IC GPIB Connector/Address Switch Assembly or with a 114597 Serial Connector Kit.* Uses 9-32 Vdc power.
-
Product
Serial I/O Expansion
PCM-G-COM8
-
The PCM-G-COM8 is an 8-channel PC/104-compatible serial module. It is well suited for embedded applications requiring a large number of serial I/O ports. Each channel supports RS-232, RS-485, and RS-422 electrical levels to interface to a wide variety of serial communications devices such as modems, data collection equipment, and distributed I/O terminals. The PCM-COM8 will operate over the full industrial temperature range of -40° to +85° Celsius.
-
Product
USB-485/2, 2-Port, USB, RS485/RS422 Serial Interface Device
778476-02
Serial Interface
The USB‑485/2 interface transforms your USB port into a single asynchronous serial port for communication with RS485 and RS422 devices. You can use a USB‑485/2 port as a standard serial port from your application, including RTS/CTS hardware handshake lines. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.
-
Product
Multiprotocol P104Plus Interface Board for Embedded Applications or Avionics Test & Simulation Applications
EXC-4000P104plus
-
The EXC-4000P104plus is a multiprotocol P104plus interface board for embedded applications or avionics test and simulation applications. Each board holds up to five independent modules. Two on-board modules use the MIL-STD-1553 communications protocol (M4K1553Px); another on-board module uses the ARINC-429 communications protocol; two additional detachable modules can be any one of the following types:M4K1553PxS (Single Function - RT validated) This module operates as a Bus Controller, Remote Terminal or a Bus Monitor. This module qualifies for airborne applications.M4K1553Px (Multi Function) This module operates as a Bus Controller, up to 32 Remote Terminals and as a Bus Monitor. Supports an Internal Concurrent Monitor in RT and BC/RT modes.M4K1553Px(S)-1760 Same as M4K1553Px(S) plus MIL-STD-1760 options.M4KMMSI Mini Munitions Store Interface module. Supports RT, BC/Concurrent-RT/Concurrent Monitor and Bus Monitor modes. Up to 8 hub ports EBR-1553 [10 Mbps 1553 protocol using RS-485 transceivers] and 1 monitor output.M4KH009 Based on our H009 family. This module operates as a Central Computer Complex (CCC) and/or up to 16 Peripheral Units (PUs) simultaneously, or as a Bus Monitor. In addition, a Concurrent Bus Monitor enables concurrent monitoring of the bus during CCC and PU simulation.M4K429RTx Based on our ARINC 429RxTx board. This module supports either five or ten ARINC 429 channels each of which can be configured in real time as a receive or transmit channel.M4K708 This module supports two channels of ARINC 708/453, each one selectable as either transmit or receive.M4KSerial This module supports up to 4 independent channels of serial communications, each of which can be selected as RS485, RS422 or RS232.M4KDiscrete This module supports 20 selectable input/open collector output discretes. The module supports TTL (0 to 5 volts) or avionics (0 to 32 volts) voltage levels.M4KCAN This module supports up to 6 independent channels of CAN 2.0B protocol with standard and extended message frames and message identifiers.
-
Product
Sensor
Hyperion Fluorescein
-
The Hyperion Fluorometer sensor range delivers a high-performance measurement of Chlorophyll A, Fluorescein, Rhodamine and Phycocyanin. Offered as standard in a 6000m depth rated, titanium housing the Hyperion Fluorometer has a wide range (9-28V DC) isolated power supply, data output up to 16Hz and RS232, RS485 and Modbus communications.
-
Product
Modbus RTU Rs486/232/422
-
It provides client/server communication between devices connected to different types of buses or networks. Modbus-RTU (Remote Terminal Unit) means that the Modbus protocol is used on top of a serial line with an RS-232, RS-485 or similar physical interface.
-
Product
15-CH Isolated Digital Output Module
ND-6056
Data Acquisition Module
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.