I²C
A slow Inter-Integrated Circuit bus protocol.
-
Product
MIL-STD-1553 A / B Test And Simulation VXIbus Module
VXI-1553
-
*1, 2, 4 or 8 channels*Simultaneous bus controller, 31 remote terminals, bus monitor*Error entry and detection*FPGA based hardware architecture*Multi-level trigger for data acquisition and filtering*10 programmable, discrete I / O*IRIG-B timecode encoder / decoder with free-running mode*Real-time recording and physical bus playback*Supports: C, C ++, C # and .net*VISA based VXI Plug & Play driver*Optional twinax front end
-
Product
Enlarge Environmental Chamber
REXMED REC-250
-
MOD. REC-250, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc
-
Product
32-CH Discrete Output Module
HSL-DO32-M-N/HSL-DO32-M-P
Digital Output Module
Slave ID consumption: 2 consecutive from odd"N" type for NPN sinking type outputSwitch capacity: Single channel 500 mA; all channels 60 mA at 24VDCPhoto couple isolation voltage: 2500 VrmsResponse time: ON→OFF: 180µs, OFF→ON :1.2µsLED indicator: Power, Link and Output statusPower supply: +10V to +30 VDCOperating temperature: 0 to 60°C
-
Product
Mini Palm Size Infrared Thermometer
IR-101
-
Shenzhen Calibeur Industries Co., Ltd..
'-Temperature range: -20~200°C (0~ 400°F);'-Accuracy: ±2.5°C (-1°C ~320°C ), ±4°C(<-1°C);'- Field of View: 8:1; '-℃/℉ exchange;'- Max/Min function'-Backlight, LCD Display;'- Size:65x113x29mm'- Weight: 80g'-Power: 12V 23A Battery(not included)
-
Product
DIN-Rail Power Meter
EVA-P220
Power Meter
Providing power parameters ; V, I, P, Q, kWh, kVarh etc.DIN-Rail mounting with high accuracy measurementFlexible phase wire connection. 1P2W/1P3W/3P3W(1/2/3CT)/3P4W(1/3CT)Front display with buttons for on-site operationCO2 emission calculation
-
Product
NI-9203, 200 kS/s, ±20 mA, 8-Channel C Series Current Input Module
783731-01
Current Input Module
200 kS/s, ±20 mA, 8-Channel C Series Current Input Module - The NI‑9203 is intended for high-performance control and monitoring applications. It features programmable input ranges and variable connectivity options. To protect against signal transients, the NI‑9203 … includes a channel‑to‑earth ground double‑isolation barrier (250 Vrms isolation) for safety and noise immunity.
-
Product
MIL-STD-1553 A, B Simulator/Analyzer/Tester
CIC201
-
MIL-STD-1553 A, B Simulator/Analyzer/Tester - CIC201B VME/VXI B Size Interface, CIC201C VME/VXI C Size Interface - The CIC201 can be used for Validation Testing, Production Testing, full bus simulation and monitoring, as a general purpose 1553 interface or a stand alone bus Analyzer. For precise message scheduling and measurements, the Major and minor frame times are independent of message sequences or retransmissions on errors and the start of all command messages are independent of message length, response time or length of response. Message timing is calibrated and RT responses have low jitter.
-
Product
Laser Distance Meter
KM 973
-
Kusam Electrical Industries Limited
• Measuring Range : 0.05 to 40M (KM 973) , 0.05 to 70M (KM 975), 0.05 to 100M (KM 976) • Measuring Accuracy : ± 2 mm• Display Accuracy : 1 mm• Laser Classification : Class 2M II• Laser Type : 620-690nm, <1mW• Protection against splashes and dust : IP 54• Temperature range for Operation : 0°C to +40°C• Temperature range for Storage : -20°C to +70°C• Laser Switch-OFF Automatically : After 30 Seconds• Instrument Switch-OFF Automatically : After 3 Minutes• Area, Volume Measuring.• Indirect (Pythagoras) Measurement.• Plus-Minus Method.• Continuous Measurement.• Minimum / Maximum Measurement.• Display illumination.• Show beep.• Battery Life : 5000 to 8000 Measurements• Battery Selection : Lr6 (AA) 2 x 1.5V• Dimensions : 121(L) x 56(W) x 28(H) mm• Weight : 150g
-
Product
Functional Testing For Critical Software
RapiTest
-
*Requirements-based testing for Ada, C & C++ on-host & target*Reduce test authoring effort through easy-to-use test formats*Manage project artifacts with requirements traceability*Simplify verification through integration with your CI tool*Produce evidence for DO-178 and ISO 26262 certification
-
Product
L-Band RF Tuner and 2-Channel 500 MHz A/D with Virtex-7 FPGA - 3U VPX
Model 52791
-
- Accepts RF Signals from 925 MHz to 2175 MHz- Programmable LNA handles L-Band input signal levels from -50 dBm to +10 dBm- Programmable analog downconverter provides IF or I+Q baseband signals at frequencies up to 123 MHz- Two 500 MHz 12-bit A/Ds digitize IF or I+Q signals synchronously; optional: 400 MHz 14-bit A/Ds- Two FPGA-based multiband digital downconverters- Xilinx Virtex-7 VX330T or VX690T FPGAs- 4 GB of DDR3 SDRAM- Sample clock synchronization to an external system reference- PCI Express (Gen. 1, 2 & 3) interface, up to x4- Clock/sync bus for multimodule synchronization- Optional user-configurable gigabit serial interface- Optional LVDS connections to the Virtex-7 FPGA for custom I/O- Supports GateXpress® FPGA-PCIe Configuration Manager- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
Product
Alumel, Type K (°C) Contacts
-
Thermocouple contacts are manufactured from chromel or alumel alloys and are color-coded for easy identification. They are crimp terminated and easily inserted into connector modules and readily removed using a special removal tool.
-
Product
NI-9215, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
779138-01
Voltage Input Module
±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9215 performs differential analog input. The module contains NIST-traceable calibration, a channel‑to‑earth ground double isolation barrier for safety and noise immunity, and high common-mode voltage range. It is also offered in two connectivity variants: 10‑position screw terminal or BNC.
-
Product
Muffle Furnace
-
1100°C, 1200°C & 1300°C Laboratory chamber furnaces (CWF) - Maximum operating temperatures of 1100°C, 1200°C or 1300°C
-
Product
Extreme Temperature Active Probe, 1.5 GHz
N2797A
Oscilloscope Probe
Testing devices over extreme temperature ranges is quite common these days. The N2797A single-ended active probe is the industry’s first low-cost high input impedance active probe with rugged probe tips for environmental chamber testing of ICs and devices. It gives the ability to probe signals at drastic temperature swings ranging from –40 °C to +85 °C. The probe provides 1.5 GHz of bandwidth and a 2 m long cable.
-
Product
Process temperature meter
PCE-IR 6
-
Electronic Product Test & Design
Its infrared sensor has an optical resolution of 50:1 and accurately measures temperatures from a distance. The infrared temperature meter is equipped with various relays that enable an alarm to be triggered and makes a cooling or heating control possible.The measurement range is -50 ... 900 ° C, with a resolution of 0.1 °C. The emissivity of the infrared temperature meter can be freely set, which makes the pyrometer PCE-IR 6 useful for a variety of surfaces in safety engineering, plastics processing and steel processing.
-
Product
cRIO-9042, 1.60 GHz Quad-Core CPU, 4 GB DRAM, 4 GB Storage, -40 °C to 70 °C, Kintex-7 70T FPGA, 4-Slot CompactRIO Controller
785622-02
Embedded Controller
1.60 GHz Quad-Core CPU, 4 GB DRAM, 4 GB Storage, -40 °C to 70 °C, Kintex-7 70T FPGA, 4-Slot CompactRIO Controller - The cRIO-9042 is a rugged, high-performance, customizable embedded controller that offers Intel Atom quad-core processing, NI-DAQmx support, and an SD card slot for data-logging, embedded monitoring, and control. It includes a Kintex-7 70T FPGA with LabVIEW FPGA Module support for advanced control and coprocessing. The controller provides precise, synchronized timing and deterministic communications using Time Sensitive Networking (TSN), which is ideal for highly distributed measurements. This controller offers several connectivity ports, including Gigabit Ethernet, USB 3.1, USB 2.0, RS232, and RS485 ports. You can use the USB 3.1 ports to add a local human machine interface and program, deploy, and debug software, which simplifies application development.
-
Product
8-Slot Distributed DA&C System For Ethernet
ADAM-5000/TCP
Data Acquisition System
10/100Base-T auto-negotiation high-speed communication portSupports Modbus/TCP for easy integrationSupports UDP event handling function1500 VDC isolation for Ethernet communicationProvides C and .NET class library to develop applicationsBuilt-in watchdog timer for system auto-resetWindows utility- I/O modules configuration and calibration- Network auto searching- Data stream setting- Current status monitoring and alarm trigger8 I/O slots for up to 128 points data monitoring and controlAllows concurrent access for 8 host PCsAllows remote configuration via EthernetUp to 100 m communication distance w/o repeaterARM 32-bit RISC CPU
-
Product
Rack Mount Type Amplifiers
-
Amplifiers for each of O-, S-, C- and L-bands– Compatible with high-speed transmission (up to 100 Gbps)– Available for all signal types and protocols– Compatible with transmitters from all manufacturers– Compatible with SNMP
-
Product
L-Band RF Tuner and 2-Channel 400 MHz A/D with Kintex UltraScale FPGA - XMC
Model 71891
-
- Jade Xilinx Kintex UltraScale FPGA Products and Navigator Design Suite Software Video- Jade Xilinx Kintex UltraScale FPGA Family Brochure- Accepts RF signals from 925 MHz to 2175 MHz- Programmable LNA handles L-Band input signal levels from -50 dBm to + 10 dBm- Programmable analog downconverter provides IF or I+Q baseband signals at frequencies up to 123 MHz- Two 400 MHz 12-bit A/Ds digitize IF or I+Q signals synchronously- Two FPGA-based multiband DDCs (digital downconverters)- Xilinx® Kintex® UltraScale™ FPGA- Five GB of DDR4 SDRAM- Sample clock synchronization to an external system reference- PCI Express interface (Gen. 1, 2 & 3) up to x8- Clock/sync bus for multimodule synchronization- Optional LVDS and gigabit serial connections for FPGA for custom I/O- Navigator BSP® for software development- Navigator FDK® for custom IP development- Free lifetime applications support- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
Product
Chromel, Type K (°C), Thermocouple Contacts
Thermocouple Contact (ITA)
Thermocouple contacts are manufactured from chromel or alumel alloys and are color-coded for easy identification. They are crimp terminated and easily inserted into connector modules and readily removed using a special removal tool.
-
Product
Low Cost Emulator
EB-51X2
-
* Emulates 8051 Derivatives with 6/12 Clocks/Cycle * 64K Code And 64K Data Memory * Memory With Mapping Capabilities * Real-Time Trace * Frequency Range up to 40MHz * Source-Level Debugger For C And Assembler * MS-Windows Debugger Software * Performance Analyzer * Emulation Header and Signal Testpoints * Serially Linked to IBM PC at 115Kbaud
-
Product
Sound Level Calibrator
521
-
Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.
-
Product
ARINC-429/717 XMC Interface For SBCs, VPX, VME, CPCI/PXI Systems
XMC-A429
Interface Card
The card design is based on the industry’s most advanced 32-bit ARINC FPGA protocol engine, AltaCore™, and a feature-rich application programming interface, AltaAPI™, which is a multi-layer ANSI C and Windows .NET (MSVS 2005/08/10 C++, C#, VB .NET, LabVIEW, RTOS) architecture. This hardware and software package provides increased system performance and flexibility while reducing integration time.
-
Product
Chassis
-
United Electronic Industries, Inc.
Two independent Gigabit (1000/100/10Base-T) Ethernet InterfacesOne port for Control, the second for diagnostics orBoth ports bonded/teamed for redundant network accessCompact: 2.7" x 4" x 4.1"Over 60 different I/O configurationsRugged: 100 g shock, 5 g Vibration, −40 to +70 °C, 0 – 70,000 feetReal-time: 1000 I/O scans in < 1 millisecondInter-device sync interface
-
Product
Digital Shore C Rubber Hardness Tester
HS-C
-
Shenzhen Chuangxin Instruments Co., Ltd.
HS-C is a digital micropore hardness, is for the foamer rubber and plastic microporous material when the compression rate is 50%and the stress is more than 0.5 kg/cm
-
Product
NI-9230, 3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
783824-02
Sound and Vibration
3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9230 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9230 is also compatible with smart TEDS sensors. The NI‑9230 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
Product
EN50155 Managed Ethernet Switch
EKI-9512E-4GMX
Ethernet Switch Module
8 x M12 D-Coded 10/100 Mbps ports + 4 x M12 X-Coded 10/100/1000 Mbps ports, Complies with EN50155 & EN50121-3-2, Operating temperature: -40 ~ 75°C, Operating power input range: 16.8~137.5VDC. Supports X-Ring Pro for rapid and predictable convergence, Supports IXM for fast and easy maintenance, Supports N-Key for quick configuration and backup, M12 connector with IP67 rugged housing.
-
Product
Development System
FE-SND2
-
* Emulates Atmel AT89C51SND2 Microcontrollers * 62K Code Memory * Real-Time Emulation * Frequency up to fmax * ISP and X2 Mode Support * Windows Debugger For C, C++ and Assembler * USB or RS-232 Linked to PC * C Compiler and Assembler
-
Product
CS | CSmicro Series Infrared Thermometer
-
Optris offers the industrial benchmark within affordable industrial pyrometers regarding the sensing heads’ size, robustness, and temperature rating. The different spectral options allow temperature measurements of plastics, metal, glass, and ceramics from -50-1030 °C with temperature resolution down to 25mK. Different optical options support a high distance-to-spot-size ratio to ensure an optimal focus on the target for high-temperature accuracy.
-
Product
Erbium Doped Fiber Amplifier
EDFA
-
EDFAs are based on the light amplification in erbium-doped fiber, which are optically pumped by means of 980 nm or 1480 nm light sources. In this way, the light of a larger wavelength within the C or L band applied to the input of the amplifier is amplified, thus widening the range of optical communication links. EDFAs typically operate in saturation and the average signal power determines the average gain. The dynamics of EDFA are unaffected by the sequence and dynamics of a digital signal or channel interaction in DWDM systems. As a result, multiple channels can be bundled within the total erbium spectral amplification bandwidth. However, the total average output power in both cases is determined by the saturation power of the specific EDFA.





























