Leakage Testers
Look for unintended path of current.
-
Product
MXE EMI Test Receiver, 3 Hz to 44 GHz
N9038B
Receiver Tester
The Keysight N9038B is a standards-compliant MXE EMI test receiver and diagnostic signal analyzer built on an upgradeable platform. You choose the frequency coverage you need to fully test devices with outstanding accuracy and sensitivity across required ranges.
-
Product
Bit Error Rate Tester - PXI
BERT 1001/1005 Series
Tester
The BERT is 2 or 4-channel PPG and Error Detector for the design, characterization and production of optical transceivers and opto-electrical components at data rates up to 30 Gb/s.With scalability and exceptional signal fidelity, it is a cost effective test solution for 400 Gb/s communication eco-systems.
-
Product
KVS Rugged Igniter Tester With Current Monitor
4314
Tester
The Valhalla Scientific Model 4314 KVS Digital Igniter Tester is designed to provide extremely safe and reliable resistance testing of explosive or volatile devices. Proven uses include fuses, squibs, igniters, explosive bolts, automobile airbag initiators and many others.
-
Product
64 Gbaud High-performance BERT
M8040A
Bit Error Rate Tester (BERT)
The Keysight M8040A is a highly integrated BERT for physical layer characterization and compliance testing. With support for PAM-4 and NRZ signals and data rates up to 64 Gbaud (corresponds to 128 Gbit/s) it covers all flavors of 200 and 400 GbE standards.
-
Product
Universal A/V Tester
Tester
This tester was built for our client with the specific requirement that specific UUTs can be added to the system by our client. We handled developing test software for the first 2 UUTs utilizing an open programming structure that allowed programming modules to be strung together to create test programs for any additional UUT that our client wants to add in the future.
-
Product
120 GBd High-performance BERT
M8050A
Bit Error Rate Tester (BERT)
The Keysight M8050A high-performance bit error ratio tester (BERT) enables accurate characterization of receivers used in next-generation data center networks and server interfaces. With uncompromised signal integrity, support for NRZ, PAM4, PAM6, and PAM8 signals, and data rates up to 120 GBd, the flexible architecture of the M8050A supports 1.6T pathfinding as well as other leading-edge technologies.
-
Product
Open/Short Tester for Reverse Engineering Applications
Panther 2K-CT
Tester
Qmax Test Technologies Pvt. Ltd.
Panther 2K-CT is a versatile open\Short tester designed especially for reverse engineering application of tracing circuits of undocumented PCBA’s.Its innovative measurement technology helps tracing PCB tracks between components in a given circuit board. It can accommodate various types of clips\grabbers and connectors to access the device pins to trace the connectivity. Its user friendly software guides the user to place and move cluster of IC clips and probes to learn the connectivity and to generate netlist.
-
Product
Analog AC Leakage Current Clamp Tester
MCL-350
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*High accuracy analog display with strong taut band meter.*3 years long battery life.*Meter lock function and data output for recorder.*Filter rejection for high frequency noise
-
Product
Earth Leakage
-
Earth leakage is when the current flowing in a system finds an alternative return path other than active and neutral conductors.
-
Product
Earth Leakage Relays
-
Variable Earth Leakage Relays in compact 35mm din rail mounting cases for use on 3 phase electrical systems.
-
Product
Leakage Current Clamp Tester with Bluetooth40mmφCT, ACA
M-1141X
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Waveform display is possible with connection to a smartphone・Measurement data is to be accumulated in the server, and it is available for graph and CSV output・Auto 5-range : AC 30mA / 300mA / 3A / 30A / 300A・CT inside diameter : φ40mm・Minimum resolution : 0.01mA・Maximum value hold / Data hold function available・Band path filter with center frequency (fo = 55Hz)・Compliant with EN 61010, CAT-III 1000V / CAT-IV 600V・With backlight
-
Product
Leakage Current Monitor
-
To alert utility-line workers of overcurrent conditions on such aerial devices as insulated ladders and truck booms, the Chance Sentinel sounds an alarm if leakage current reaches a pre-set level.
-
Product
Error Detector Remote Head 32 and 17 Gb/s
N4952A
Bit Error Rate Tester (BERT)
The N4952A is an affordable and compact error detector remote head available in 4 to 17 Gb/s and 5 to 32 Gb/s configurations. Compatible with the N4960A Serial BERT controller, it is the perfect solution to test up to 32 Gb/s per channel for 100 Gigabit Ethernet applications and other high-data rate devices. The N4952A error detector supports PRBS or user patterns and operates up to 32 Gb/s in a single band with no gaps or missing data rates. The remote head allows the test equipment to be located very close to the device under test, eliminating the need for long cables that degrade signal quality.
-
Product
Low Leakage Switch Mainframe
B2201A
Mainframe
The B2201A reduces the cost of test by enabling characterization tests to be automated, with only slight compromise to the measurement performance of the semiconductor parameter analyzer. It supports a 4-SMU, full-Kelvin configuration and a capacitance meter, with room for future expansion. Includes 14 inputs, each with a unique internal measurement path, and a distinctive capacitance measurement compensation feature for two of the inputs. Provides front panel control via keypad or optional light pen, and supports instruments such as pulse generators.
-
Product
Earth Leakage Circuit Breakers
-
Mitsubishi Electric Automation, Inc
Like molded case circuit breakers, these circuit breakers are utilized to open/close low-voltage circuits and protect wiring by automatically closing circuits when they''re overloaded or if a short-circuit occurs. We offer a comprehensive range of circuit breakers that provide superior performance in electrical protection, isolation and power distribution applications. Our circuit breaker products comply with various standards such as JIS, IEC, EN, GB and UL/CSA, and with easy to install accesories, the Mitsubishi Electric circuit breakers are "user-friendly" and ensure the best solution for virtually every application.
-
Product
AXIe M8000 Series of BER Testers
Bit Error Rate Tester (BERT)
Simplified time-efficient testing is essential when you are developing next-generation computer, consumer, or communication devices. The Keysight M8000 Series is the highly integrated BER test solution for physical layer characterization, validation, and compliance testing. With support for a wide range of data rates and standards, the M8000 Series provides accurate, reliable results that accelerate your insight into the performance margins of high-speed digital devices.
-
Product
Mini AC Leakage Current Clamp Tester (CE)
M-140
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*40mmφCT window and ultra compact size.*Least affection from the external magnetic field.*Wide current measurements.(AC0.01mA-300A)
-
Product
Multi Circuit Leakage Current Monitor
MCM-8000
-
By connecting optional CT sensors, the instrument can measure and memorize leakage current of 8 circuits at the same time and the memorized data can be seen even during measurement.
-
Product
Clamp on AC Leakage Current Sensors
-
High Accuracy Clamp AC Leakage Sensor use permalloy magnetic cores, with small size, high accuracy, good stability, strong anti-interference ability characteristics. It is applied with double shield technology, which insure strong anti-interference ability.
-
Product
PAM4 Bit Error Rate Tester.
BERT-1102
Tester
The BERT-1102 is a 4 or 8-channel PPG and Error Detector for the design, characterization and manufacturing test of optical transceivers and opto-electrical components with symbol rates up to 29 GBaud/s in both NRZ and PAM4 formats. With scalability and exceptional signal fidelity, it is a cost-effective test solution for up to 400 Gb/s communication eco-systems.
-
Product
FA Leakage Switch Mainframe
B2200A
Mainframe
The B2200A reduces the cost of test by enabling characterization tests to be automated, without compromising the measurement performance of the semiconductor parameter analyzer. It supports a 4-SMU, full-Kelvin configuration and a capacitance meter, with room for future expansion. Includes 14 inputs, each with a unique internal measurement path, and a distinctive capacitance measurement compensation feature for two of the inputs. Provides front panel control via keypad or optional light pen, and supports instruments such as pulse generators.
-
Product
Wet Leakage Current Test
-
King Design Industrial Co., Ltd.
The outdoor solar module will endure the erosion of rain, fog, snow and sandstorm. To make sure that solar module will not wet leakage current accident and tolerate huge load pressure in such harsh conditions, we adopt wet leakage current to simulate the above weather conditions.
-
Product
Multi Circuit Leakage Current Monitor
MCM-8000
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
●The leakage current of max.8 circuits at the same time.●Easy for data management (storage by CSV formula)●Cost performance, high-speed sampling with high-frequency cut function.
-
Product
Digital Ior Leakage Current Clamp Tester
MCL-400IR+
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
・About Ior Leakage CurrentRecently, the leakage current clamp meter is widely used for insulation control of low voltage circuit as the supplementary method of the insulation resistance measurement. The control of leakage current has the advantages to enable the prediction of insulation condition in the electrical power line without having to shut off the power. The leakage current (Io) includes the capacitive leakage current (Ioc)originated in the capacitance and the resistive leakage current (Ior) originated in the insulation resistance each related to the ground. It is considered that the measurement of resistive leakage current (Ior) is the very useful and effective method for the insulation control of low voltage circuit. However, it was difficult to measure the resistive leakage current (Ior)with traditional leakage current clamp meter. MCL-400IR new digital clamp tester enabled the measurements of the resistive leakage current (Ior)without voltage input(phase detection).
-
Product
Leakage Current Sensors / Small Current Sensors
-
ChenYang Technologies GmbH & Co. KG
This current sensor is based on magnetic modulation and compensation principle, and can beused for measurement of small DC current and leakage current, current difference between two ormore conductors.
-
Product
Leakage Current Alarm Signaler
MPU-1
-
MPU-1 is dedicated to control (measure) leakage current in AC, low and medium voltage power networks. It is designed to make measurements, which results define network's safety condition for leakage current. The device enables to set limit for maximum safe value of flowing leakage current and for values above this limit visual and sound alarm is activated.
-
Product
MTM-Bus Tester
PXIe-1149.5
BUS Tester
The Corelis PXIe-1149.5 is a versatile, multi-mode instrument for interfacing with MTM-Bus modules. The PXIe-1149.5 adds MTM-Bus master, slave, and monitoring with full IEEE-1149.5 electrical and protocol compatibility with a standard PXIe interface for convenient integration into any Test Program Set (TPS).
-
Product
Non-contact Io/Ior Leakage Clamp Meter
MCL-500IRV
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Safety by non-contact sensor, not touching live part directly (prevention of electric shock, short-circuit, etc.).・Easy to carry and operate, clamp CT + display part integrated type.・Measurable line current + leakage current + resistive leakage current by one unit.・Available direct voltage input at live part as ordinary.・True RMS measurement (I, Io, V).・With filter switch to cut high frequencies.
-
Product
AE Valve Leakage Detector
SVLD1
-
Through acquisition, processing, and calculation of acoustic emission signal of the valves, SVLD1 could generated root-mean-square voltage (RMS), average signal level (ASL) and power (P) parameters as which could judge the leakage. Meantime, you can pre-calibrate the leakage quantity for the specified valve, and calibration curve of parameters and leakage could be calculated by SVLD1, so as to give the valve leakage reference value during the test.