Reactive Load Banks
Provide both lagging and leading power factor loads.
See Also: Load Banks, AC Load Banks, DC Load Banks, Inductive Load Banks, Resistive Load Banks
-
Product
2 Way GPS / GNSS Signal Splitter Passive, 1-2 GHz, N Type, DC Block+200Ω Load 2 Ports
GPS202
-
INSTOCK Wireless Components, Inc
PS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.2 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy N Type Female (Jack) 50 Ohm
-
Product
Load Cell Amplifier
-
Xiamen Elane Electronics Company, Ltd
: 0-50 degrees. Humidity: 30 to 80 percent, non-condensing.Power Supply Requirements:Power Supply voltage: 9 volts DC.Operating current: 5mA, plus bridge current.Bridge Input:Excitation voltage: 5 volts.Bridge Type: Full Wheatstone Bridge.Voltage Output Range: From 0 volts to 4.3 volts.
-
Product
Signal, Module, Receiver, QuadraPaddle, iCon Series, 160 Position, loaded w/ Twin Female Contacts and Round Posts
510160122
Receiver Module
Fully Loaded with Twin Female Contacts and Round Posts (Adapter Pins) (p/n's 610138200 and 610138117).Primary mating module 510161101. (May mate with other ITA modules, as well.)
-
Product
Signal / Micro Power/ Micro Coax, Module, Receiver, QuadraPaddle, iCon Series, 100/15 Position, loaded w/twin female contacts
510160112
Receiver Module
This module comes fully loaded with twin female contacts (p/n 610138200), iCon modules mount from the rear of the iCon/i1 receiver allowing installation and removal of pre-wired cable blocks. Primary mating module 510161107. (May mate with other ITA modules, as well.)
-
Product
Open-Short-Load RF calibration kits
-
Open-Short-Load RF calibration kits from Fairview Microwave are available with Type N or 7/16 DIN connectors. Type N open-short-load RF calibration kits have male or female genders, 7/16 DIN open-short-load kits are male gender. Type N open-short-load (OSL) calibration kits for RF have a minimum frequency of 0 (DC) and a maximum frequency range between 4 GHz and 6 GHz. Type N open short load kits for calibration have a maximum power handling of between 1 Watt and 2 Watts.
-
Product
110V / 100 Amp Load
BD12-110P-48/24
-
For Battery Discharge testing and Power Supply testing. This particular Load has been designed to operate with 110V battery systems and is extremely costeffective.
-
Product
Dual DC Electronic Load
3330F Series(40W~250W)
-
3330F Series Dual DC Electronic Load is a two load unit in one module. Each 3330F Series module has its own control and display panel, CC/CR/CV/CP/ Dynamic modes, plug in 3300F with 150 sets Store/Recall memory which provides load set-up more efficiently,also can be remote controlled via RS232、Ethernet、USB and GPIB interface.
-
Product
Rod End Load Cells
-
Our rod-end load cells are designed for integration into tension measurement. They are versatile, durable, and fit easily into small spaces such as inline with vehicle tie rods.
-
Product
Dynamic Mechanic Loading Tester
-
King Design Industrial Co., Ltd.
*Complies with IEC 61646, IEC 61215 mechanical load test specification. * Air pressure is adjustable, output range is from 2400pa to 5400pa ±5% . * Maximum measurement range: 220 x 260 cm. * Apparatus structure material:aluminum-extruded. * Fixtures and holders can be customized design for requirement of testing module. * Manual operation is simple; manual maintenance is easy.
-
Product
High Power DC Electronic Load
36000A Series(50KW / 60KW)
-
36000A Series has its own control and display panel, CC / CR / CV / CP / Dynamic modes, 150 sets Store / Recall memory which provides load set-up more efficiently, also can be remote controlled via GPIB、RS232、USB and LAN interface.SHORT time setting and SHORT_VH, SHORT_VL setting function, also can measure Short Voltage and Current.
-
Product
230V / 36 Amp Load
EL08-230M
-
For High Voltage UPS Battery Testing and Power Supply testing. This particular Load has been designed to operate with UPS Battery Systems and Telecom Rectifiers and Power Supplies with output Voltages in the range of 153V to 230V and is extremely cost effective.
-
Product
Receiver, I2 Micro ICon, 120/12 Position Hybrid, Loaded With Twin Female Contacts (610 138 200)
310130104
Receiver
The i2 Micro iCon receiver is a one piece connector capable of holding up to 120 Signal QuadraPaddle contacts and 12 Micro Coax or Micro Power. QuadraPaddle modules are molded on .100” (2.54 mm) centers to meet the need for high-density I/O in a compact assembly. This i2 receiver is pre-loaded with twin female contacts, QuadraPaddle Part # 610 138 200. Accessories such as keying pin kits, protective covers, and strain relief are available.
-
Product
ElectroForce Load Frame Instruments
-
The design of new materials and products requires a thorough assessment of material properties and complete performance evaluation within, and sometimes beyond, the intended end-use.
-
Product
Robotic Sample Loading Systems
-
Below you can see examples of two systems using our robotic sample loading system. Many other automated microscopy systems are possible using our components.
-
Product
Digital Roller Brake Tester for Cars and Vans up to 4.0 T Axle Load with 2 x 4 kW Drive Motors and Max. Track Width of 2,200mm
C_MBT C 4.0 W220 STOCK | VP 210165
-
Maschinenbau Haldenwang GmbH & Co. KG.
Digital roller brake tester for cars and vans up to 4.0 t axle load with 2 x 4 kW drive motors and a max. track width of 2,200 mm.Basic version - available ex stockincl. specific option package.Particularly suitable as stand-alone tester or as part of car reception and diagnostic test lanes.
-
Product
Signal, Module, Receiver, QuadraPaddle, 480 Position, Fully Loaded With Twin Female Contacts (610138200)
510150131
Receiver Module
QuadraPaddle modules are molded on .100” (2.54 mm) centers to meet the need for high-density I/O in a compact assembly. Allowing flexible configuration options with standard commercial connectors, QuadraPaddle modules are designed to fit any VPC pin and socket-based mass interconnect system. Available in 192 and 480 contact positions, QuadraPaddle modules accept standard .100” (2.54mm) pitch headers, breadboards, and connectors for direct PCB, ribbon cable, and other connections as well as discrete wiring.
-
Product
Signal, Module, Receiver, QuadraPaddle, 90 Series, 192 Position, Fully Loaded w/ Twin Female Contacts
510150130
Receiver Module
Primary mating module 510151105. (May mate with other ITA modules, as well.)
-
Product
Clamp type AC Current Sensor/for Load Current Measurements(CT Series)
CT-33S
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Ultra compact size*AC 1A~200A*Current measurements of feeder
-
Product
External Load Module
ELM
-
Circuit breakers are often overlooked during maintenance of electrical systems in aircraft, or often only verified for open and closed states. To test the true functional purpose of a circuit breaker it requires the application of current in excess of the rated trip value and then measure the time for the breaker to actually trip. This is the only way to verify that a circuit breaker will react as designed if an electrical failure occurs.
-
Product
PXI MUX 8 Banks of 8 Channel 1 Pole
40-610-021-8/8/1
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
High Power DC Electronic Load
34000A Series(5KW~40KW)
-
34000A Series has its own control and display panel, CC / CR / CV / CP / Dynamic modes, 150 sets Store / Recall memory which provides load set-up more efficiently, also can be remote controlled via GPIB、RS232、USB and LAN interface.SHORT time setting and SHORT_VH, SHORT_VL setting function, also can measure Short Voltage and Current.
-
Product
Shear Beam Load Cell
SB-1.0
-
The Shear Beam Load Cell SB-1.0 is a single point weighing device, suitable for use in multiple applications.
-
Product
AC Electronic Load
-
AC&DC Electronic Loads are design for testing uninterruptible power supplies(UPS), Off-Grid Inverters, AC sources and other power devices such as switches, circuit breakers, fuses and connectors.
-
Product
LED DC Electronic Load Simulator
3340G Series(150W~300W)
-
Each 3340G Series module has its own control and display panel, LED/CC/CR/CV/CP/ Dynamic modes, plug in 3300F with 150 sets Store/Recall memory which provides load set-up more efficiently,also can be controlled intranet via RS232、Ethernet、USB and GPIB interface.
-
Product
Road Load Data / Durability
-
Vehicle Durability Testing and Road Load Data AcquisitionA road load data acquisition system from Dewesoft is a perfect vehicle durability testing solution for real-drive tests or tests on the road simulator test benches. Our advanced DAQ technologies will shorten time to test dramatically and make sure you get the correct measurements right the first time.
-
Product
High Power DC Electronic Load(1250V)
36300E Series(50KW/60KW)
-
36300E Series has its own control and display panel, CC / CR / CV / CP / Dynamic modes, 150 sets Store / Recall memory which provides load set-up more efficiently, also can be remote controlled via GPIB、RS232、USB and LAN interface.SHORT time setting and SHORT_VH, SHORT_VL setting function, also can measure Short Voltage and Current.
-
Product
Load Cell Power Supply
MODEL PSMR
-
The PSM-R is a self contained AC power bridge excitation supply. This device consists of a low interwinding capacitance AC transformer and a high stability adjustable linear regulator designed specifically for driving transducer bridges. DC excitation is adjustable from 4 to 15 volts output and is capable of supplying 0 to 150 mA in output current. It features remote sensing to eliminate line drop errors and very low noise. It can also be used as a high quality voltage source or reference in many applications. AC input requirements are 105 to 125 VAC at 60 Hz.





























