Visual Fault Locators
Apply light to optical fibers, enabling visual inspection to determine integrity.
See Also: VFL
-
Product
Optical Fiber Identifier
AFI-400
-
Shanghai Fibretool Technology Co.,Ltd.
AFI-400 Optical Fiber Identifier is an important tool for optical maintenance, which is used for nondestructive fiber identification work, can be detect in any location of both SM and MM fiber. Meanwhile it also has Visual Fault Locator module with fault location function. It is the ideal instrument for online test.
-
Product
OTDR Tester
M-OTDR-502
-
Fuzhou Metricu Technology Co Ltd
Optical Time Domain Reflectometer Wavelength 1310 / 1550nm, max test range 150KM, Dynamic range 28 / 26dB, SOR standard data saving, create PDF/EXCEL format report, stable laser source, support CW/270/330/1000/2000Hz, Test fiber's length, loss, attenuation parameters and event map, locate connection point/fusion point, Automatic analysis of various linkers/fusion points, easy analyze of various events,Support saving curves number ≥30000pcs, loss test, detect the optical or optical components loss value, etc. Test IP camera, optical power meter, visual fault locator, RJ45 cable TDR test, cable tester, cable tracer, etc.
-
Product
Cable Fault Locators
-
Wuhan Sunma Technology Co., Ltd.
Visual Fault Locator, we can understand its function in the letter. It could be regarded to be part of OTDR and the fiber fault locator is cheap. Fiber visual fault locator is a kind of device which is able to locate the break-point, bending or cracking of the fiber glass. It can also locate the fault of OTDR dead zone and make fiber identification from one end to the other end. Designed with a FC,SC,ST universal adapter, this fiber testing red light is used without any other type of additional adapters, it can locates fault up to 10km in fiber cable. SunmaFiber also supply a new kind of Cable Fault Locator, Fiber laser tester/ fiber laser pen, it can locates fault up to 30km in fiber cable. Contact us at Sales@SunmaFiber.com or Live Chat with us. Save your money & time right now! Buy from fiber optic supplies at SunmaFiber.com with your confidence.
-
Product
2.5mm Visual Fault Locator
3105
-
Anfkom International Co.,Limited
The 3105 Pen type VFL is specially designed for field personnel who need an efficient and economical tool for fiber tracing, fiber routing and continuity checking in optical network. It includes:Finding the breakpoint, poor connections, bending or cracking in fiber optic cables.Finding the faults of OTDR dead zoneEnd-to-end visual fiber identification
-
Product
Visual Fault Locator
VFL X5003
-
Constant & stable output powerLow battery warning, reminds users to change the battery timely.Long battery life (up to 40 hours with AAA batteries)Pocket size and light weight, easy to use.Re-changeable ceramic tube, to avoid returning to manufacturer for this small fault.
-
Product
Pen-type Visual Fault Locator
PVLS Series
-
Shanghai Tarluz Telecom Tech Co., LTD
PVLS Series Pen-type Visual Laser Source (VFL) is specially designed for field operators who need an efficient and economical tool for fiber tracing, fiber routing and continuity checking in optical network. It includes threen main functions, Finding the breakpoint, poor connections, bending or cracking in fiber optic cables, Identifying the faults of OTDR dead zone, End-to-end visual fiber identification.
-
Product
650nm Visual Fault Locator
-
Shanghai Baudcom Communication Device Co.,Ltd.
Visual Fault Locator series Visual Fault Locator uses the DFB-LD as the emitting component. Driven by constant current source, the indicator can emit stable red laser.The product can be used to inspect fiber failure when they connect with optical interface and be inserted into single mode or multi mode optical fiber.It is indispensable tool in fiber project constructing, fiber net-work maintaining, optical component manufacture and research.
-
Product
Visual Fault Locators
MVFL Series
-
Shanghai Tarluz Telecom Tech Co., LTD
MVFL series Visual Fault Locators is meet the Class IIIA product, which is the easiest way to identify fibers from end to end and locate polished connector endfaces. Its red laser shines through most yellow-jacketed fibers to help you pinpoint breaks, bends, faulty connectors, splices and other causes of signal loss. The 1mW output power enable the MVFL has a reach of up to 5 km. MVFL seires VFL locates faults visually by creating a bright red glow at the exact location of the fault on single mode (SM) or multimode (MM) fibers. Due to its small size, lightweight and simple but proven design, the MVFL can accompany you anywhere In your pocket or belt pouch in harsh environment
-
Product
Visual Fault Locator
STC-VFL301
-
Shanghai Stone Communication tech Co., Ltd
STC-VFL301 is specially designed for field personnel who need an efficient and economical tool for fiber tracing, fiber routing and continuity checking in optical network.
-
Product
Tool, Locator, TriPaddle, Receiver
910104146
Locator Tool
Tool, Locator, TriPaddle, Receiver (only for contact p/n #'s 610110128 Rev C+ and 610110177)
-
Product
Visual Fault Locator
HW-205
-
Shanghai Fibretool Technology Co.,Ltd.
The HW-205 is specially designed for field personnel who need an efficient and economical tool for fiber tracing, fiber routing and continuity checking in an optical network during and after installation.- 2.5mm universal connector- Operates either in CW or Pulsed- Constant output power- Long battery life (up to 60 hours)- Laser case ground design prevents ESD damage- Portable and rugged, easy to use- Burning testing to ensure the reliability.- Optional 1.25mm connector adapter
-
Product
PXI Single Bus 32-Ch 2A Fault Insertion Switch
40-190B-201
Fault Insertion Unit
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
40-203-001
Fault Insertion Unit
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
Battery Fault Insertion Unit
Fault Insertion Unit
The Battery Fault Insertion Unit (FIU) provides intelligent switching of cell-simulation channels for the Battery Simulator 1200. The switching capability enables simulation of open-circuit and short-to-rail fault conditions on any cell channel for the purposes of battery management system (BMS) testing. Additionally, a four-wire auxiliary input allows you to connect an external digital multimeter (DMM) instrument to any cell channel for very high-accuracy bypass current and cell voltage measurements. Each FIU provides 24 independently-programmable cell-switching channels for one or two 12-cell Battery Simulator 1200 units. Additional Battery Simulator 1200 and FIU instruments can extend functionality up to 120 series-connected cell channels.
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A, Hardware Interlock
40-193A-001-HI
Fault Insertion Unit
The 40-193A-001-HI is a 7-Channel Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
Product
PXI 5A Fault Insertion Switch 10-Channel
40-196-001
Fault Insertion Unit
The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.
-
Product
PXI 34-Channel 4-Bus 2A Fault Insertion Switch
40-197A-001
Fault Insertion Unit
This 34-channel fault insertion switch is primarily intended for routing simulated fault conditions in automotive and aerospace applications involving the reliability testing of safety critical controllers. A low cost 16-channel option is also available.
-
Product
Dual Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-202
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
PXI Dual Bus 32-Chan 2A Fault Insert Switch, N/O Through Relays
40-190B-502
Fault Insertion Unit
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
Product
PXI 5A Fault Insertion Switch 5-Channel
40-196-101
Fault Insertion Unit
The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.
-
Product
Dual Bus 64-Channel 2A PCI Fault Insertion Switch
50-190-102
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
Tool, Locator, Thermocouple, ITA
910104135
Locator Tool
Used with Crimp Tool p/n # 910101102 to crimp thermocouple ITA contacts.
-
Product
Tool, Locator, Thermocouple, Receiver
910104134
Locator Tool
Used with Crimp Tool Part # 910101102 to crimp thermocouple receiver contacts.
-
Product
PXI-2510, 68-Channel, 2 A PXI Signal Insertion Switch Module
778572-10
Fault Insertion Unit
68-Channel, 2 A PXI Signal Insertion Switch Module—The PXI‑2510 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2510 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
42-203-001
Fault Insertion Unit
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
Tool, Locator, Micro Coax, Receiver
910101135
Locator Tool
Included with Crimp tool kit p/n 910101132 and kit p/n 910101131.
-
Product
PXI/PXIe Fault Insertion Switch, 64-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-112
Fault Insertion Unit
The 40-190C-112 (PXI) and 42-190C-112 (PXIe) are fault insertion switches with 64 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
40-203-002
Fault Insertion Unit
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.





























