Waveform Signal Generators
See Also: Waveform Generators, Arbitrary Waveform Generators
-
Product
P2532 General Purpose Probes
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 156Test Center (mm): 3.96Full Travel (mil): 139Full Travel (mm): 3.53Recommended Travel (mil): 93Recommended Travel (mm): 2.36Overall Length (mil): 812Overall Length (mm): 20.62Rec. Mounting Hole Size (mil): 94.5Rec. Mounting Hole Size (mm): 2.40Recommended Drill Size: #41 or 2.40 mm
-
Product
PCIe 16 Bit Arbitrary Waveform Generator - up to 40 MS/s on 4 Channels
M2P.6536-X4
Arbitrary Waveform Generator
The M2p.65xx series offers different versions of arbitrary waveform generators for PCI Express with a maximum output rate of 125 MS/s. These boards allow to generate freely definable waveforms on several channels synchronously. With one of the synchronization options the setup of synchronous multi channel systems is possible as well as the combination of arbitrary waveform generator with digitizers of the M2p product family. The 512 MSample on-board memory can be used as arbitrary waveform storage or as a FIFO buffer continuously stream data via the PCIe interface. Importantly, the high-resolution 16-bit DACs deliver four times the resolution than AWGs using older 14-bit technology.
-
Product
PXI-5651, 3.3 GHz RF Signal Generator
779670-01
Signal Generator
3.3 GHz PXI RF Analog Signal Generator—The PXI‑5651 features continuous-wave generation capabilities with FM, 2‑FSK, or OOK modulation. It uses direct digital synthesis (DDS) for high-resolution frequency hopping or phase-continuous sweeping for fixture and device characterization applications. The PXI‑5651 is ideal for clocking nonstandard sample rates, such as WCDMA signals at baseband or intermediate frequency (IF). With these versatile signal generators, you can perform analog and digital modulation through the onboard DDS circuit, which gives you frequency modulation and frequency-shift keying for applications such as bit error rate test, antenna testing, or even keyless entry. You can also perform amplitude modulation using on-off keying.
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1T
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Radius, Straight Shaft Bullet Nose, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0J
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
LXI High Voltage Switching - 20xSPST Plugin Module
65-233-703-HI
General Purpose Relay Module
The 65-233-703-HI plug-in module is part of a scalable high voltage switch platform that provides a high voltage switching solution with capability up to 7 kV. Switch arrays are created by populating the 65-200-002 scalable chassis with plug-in modules that provide access to the switches on 51-pin front panel connectors. Users can specify as many or as few plug-in modules as they require and can field upgrade the chassis to extend the number of switches.
-
Product
Multichannel Signal Generator for DOCSIS 3.1 Downstream & Upstream
CLGD DOCSIS
Signal Generator
The R&S®CLGD is a multichannel signal generator for simulating a cable TV network with full channel loading. It generates broadband data signals for DOCSIS 3.1 as well as digital and analog TV channels. Signals can be freely combined in the downstream or upstream, allowing users to simulate any conceivable channel loading scenario in the lab.
-
Product
PXI-2514, 7-Channel, 40 A PXI Signal Insertion Switch Module
778572-14
Signal Module
7-Channel, 40 A PXI Signal Insertion Switch Module—The PXI‑2514 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2514 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
Product
Alternate 0.50 (14.00) - 2.50 (71.00) General Purpose Probe
P2662BG-2V2S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 68Full Travel (mm): 1.73Recommended Travel (mil): 50Recommended Travel (mm): 1.27Overall Length (mil): 575Overall Length (mm): 14.60
-
Product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2662AG-1R1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
Product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-1W1S
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
Product
EXG X-Series RF Vector Signal Generator, 9 kHz to 6 GHz
N5172B
Vector Signal Generator
Achieve faster throughput and greater uptime with cost-effective performance optimized for manufacturing testPerform basic parametric testing of components and functional verification of receivers with industry-leading ACPR, EVM, and output powerReduce the time you spend on signal creation with Signal Studio software; purchase only the waveforms you need with 5- and 50-pack licensingMinimize downtime and expenses with self-maintenance solutions and low-cost repairs
-
Product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-1C1S
General Purpose Probe
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
Product
FieldFox Handheld Microwave Signal Analyzer, 32 GHz
N9960B
Signal Analyzer
A lightweight, durable, software-enabled, microwave signal analyzer, interference analyzer, distance-tracking generator, preamplifier, power meter, and more.
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3A
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2X
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Standard 0.39 (11.00) - 1.39 (39.00) Replaceable General Purpose Probe
MEP-30G
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 30Test Center (mm): 0.76Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 690Overall Length (mm): 17.53
-
Product
Ultra High 6.70 (190.00) - 11.80 (335.00) General Purpose Probe
EPA-4F-2
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4F
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
VXT PXIe Vector Transceiver
M9421A
Vector Signal Transceiver
Purpose-built for rapid solution creation and faster throughput in manufacturing test of wireless components, power amplifiers, and RF front-end modules Increase test density and reduce your footprint with up to four VXT instruments in one 18-slot chassis Reduce development time with open-source test libraries and reference solutions Start closer to your finish line with built-in FPGA-accelerated measurements Optimize test routines using proven software for noise figure and standard-specific measurements
-
Product
Alternate 1.30 (37.00) - 4.50 (128.00) General Purpose Probe
HPA-1C-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
PXIe-5841, 6 GHz, 1 GHz Bandwidth, RF PXI Vector Signal Transceiver
786982-01
Vector Signal Transceiver
6 GHz, 1 GHz Bandwidth, RF PXI Vector Signal Transceiver - The PXIe-5841 is a vector signal transceiver (VST) with 1 GHz of instantaneous bandwidth. It combines vector signal generator, vector signal analyzer and high-speed serial interface capabilities with FPGA-based real-time signal processing and control. The PXIe-5841 features the flexibility of a software defined radio architecture with RF instrument class performance. This VST delivers the fast measurement speed and small form factor of a production test box with the flexibility and high performance of R&D-grade box instruments. The PXIe-5841 is available with an optional high-performance local oscillator module for improved phase noise, measurement time, and EVM performance. You can use the VST to test a variety of cellular and wireless standards such as Wi-Fi 6 and 5G NR. In addition, you can expand the small, two slot 2U PXI Express form factor to support multiple input, multiple output (MIMO) configurations.
-
Product
PXIe-5667, PXI Vector Signal Analyzer
782366-01
Signal Module
Up to 7 GHz PXI Vector Signal Analyzer—The PXIe‑5667 is optimized for spectrum monitoring applications such as radio monitoring, interference detection, spectrum regulation, and related applications in line with ITU recommendations. It features real-time signal analysis and advanced signal processing using the capabilities of the built-in FPGA. The PXIe‑5667 includes options for various frequency ranges and instantaneous bandwidth.
-
Product
PXIe-5665, Up to 14 GHz PXI Vector Signal Analyzer
781775-01
Signal Module
Up to 14 GHz PXI Vector Signal Analyzer - The PXIe‑5665 is a modular, three‑stage superheterodyne analyzer that you can use as either a spectrum analyzer or vector signal analyzer. It supports RF list mode, which increases multiband measurement speed with fast and deterministic changes in configuration. In addition, you can use the PXIe‑5665 with the Modulation Toolkit to analyze custom and standard modulation formats. The PXIe‑5665 can perform measurements for a broad range of communications standards such as GSM, EDGE, WCDMA, WiMAX, LTE, Bluetooth, WLAN, DVB‑C/H/T, ATSC, and MediaFLO. Because all measurements are software defined, you can reconfigure the measurements using standard-specific toolkits. With these toolkits, the PXIe‑5665 provides a low-cost solution to high-performance RF measurements.
-
Product
PXI Vector Transceivers
Vector Signal Transceiver
Get both signal generation and analysis in one PXIe module with real-time field-programmable gate array (FPGA)-accelerated measurements for faster throughput. The PXIe vector transceiver is perfect for manufacturing test of wireless devices, RF power amplifiers, and front-end modules.
-
Product
Alternate 1.30 (37.00) - 4.50 (128.00) General Purpose Probe
HPA-1G-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
PXIe Microwave Signal Generator
LSX4091X
Microwave Signal Generator
The LSX4091X is a 40GHz Single Channel PXIe Microwave Signal Generator that offers industry leading performance, in a modern modular 2 slot PXIe format that can be used on the desk, embeded in a system or or easily scaled up to multiple channels ATE systems.
-
Product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-4
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
Product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-9
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4G
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53