Thermal Conductivity
See Also: Conductivity Meters
-
Product
Thermal Conductivity Analyzer
Model 2000B
-
Teledyne Analytical Instruments
The Series 2000 represents a complete line of Thermal Conductivity Detector (TCD) based analyzers which can be applied in a wide range of applications and industries. By using field proven filament-based and semiconductor based TC detectors, Teledyne is able to continuously monitor hydrogen and a variety of other gases of interest in either binary or multi-component sample gas streams.
-
Product
Thermal Conductivity Apparatus
-
Objective Thermal Conductivity of Liquids & Nanofluids & Engine Oils etc.
-
Product
Portable Thermal Conductivity Meter
TLS-100
-
The TLS-100 is a portable thermal conductivity meter used to measure thermal conductivity and thermal resistivity at the push of a button. Each TLS-100 comes equipped with a 100 mm sensor for testing soil, polymers, and other soft materials. An optional 50 mm sensor was designed for testing harder materials, like rock and concrete. The collected data is automatically analyzed, and results are displayed instantly.
-
Product
Thermal Conductivity Analyzer
TCi
-
The default C-Therm TCi Thermal Conductivity Analyzer employs the Modified Transient Plane Source (MTPS) technique in characterizing the thermal conductivity and effusivity of materials.
-
Product
Flat-plate Thermal Conductivity Tester
-
TESTEX Testing Equipment Systems Ltd.
Flat-plate Thermal Conductivity Tester, to determine the thermal conductivity of various fabrics, quilting products, and other heat insulation materials.
-
Product
Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion Infrared and Thermal Conductivity Detection
836 Series
-
The ONH836 Oxygen/Nitrogen/Hydrogen Elemental Analyzer is designed for wide-range measurement of oxygen, nitrogen, and hydrogen content of inorganic materials, ferrous and nonferrous alloys, and refractory materials using the inert gas fusion technique.
-
Product
Thermal Conductivity Gas Analyzer
CI2000-RQD
-
Shanghai ChangAi Electronic Science & Technology Co.,Ltd
Determining gas concentrations by measuring the thermal conductivity of the gas, CI2000-RQD analyzer uses advanced thermal conductivity sensor with single chip technology. It adopts platinum thread as sense organ to make up Imbalance Bridge, which output signal has a relationship with tested gas volume. And the single chip will magnify, sieve wavelength, modify linearly and criteria the signal by electric procedure.
-
Product
Thermal Conductivity Analyzers
-
Teledyne Analytical Instruments
Thermal Conductivity Analyzers by Teledyne Analytical Instruments
-
Product
Thermal Conductivity & Diffusivity Meters
-
Thermal conductivity, thermal diffusivity and specific heat capacity define a material’s ability to store and transfer heat. The precise and accurate measurement of these properties is critical for any process or material, which experiences a large or fast temperature gradient, or for which the tolerance for temperature change is exacting.
-
Product
Scanning Thermal Microscopy Module
VertiSense™
-
SThM module for thermal conductivity contrast and a temperature contrast imaging. Supports Contact, Tapping™ and Peak Force Tapping modes. Plug-in module, compatible with most commercial AFMs. Real temperature measurements up to 700° C. Ultra-low noise, high speed amplifier. Innovative probe design.
-
Product
Surface Mount Frequency Synthesizers
-
Corech Surface Mount Frequency Synthesizers series packs impressive low phase noise of -90dBc/Hz@1kHz, low spurious of -50dBc to -70dBc, high temperature and corrosion resistance, long operating life, temperature uniformity, and good thermal conductivity. These outstanding performance make it suitable for high-reliability and environmentally stressful applications including communication systems, test and measurement equipment, radar systems etc.
-
Product
1 kW and 2 kW Laser-Based Floating Zone Furnace
Laser Furnace
-
The 1 kW and 2 kW laser furnace for single crystal fabrication is based on a design and developed in close cooperation with the RIKEN Center for Emergent Matter Science under the leadership of Yoshio Kaneko. Both melting zones have 5 lasers each, which guarantees a high uniformity of power density in the melting zone range. The laser profile has been optimized to reduce thermal stress during the crystal growth process. In addition, the system includes an integrated temperature sensor for real-time temperature monitoring. Temperatures up to 3000 °C can be reached and therefore materials with a very high vapor pressure, a narrow temperature range of the melt, a high thermal conductivity coefficient and incongruent melts can be melted.
-
Product
TIM Tester
-
The Analysis Tech TIM Tester 1300 is an automated test system for measurement of thermal impedance and conductivity on thin, thermally conductive materials of the type frequently used for electronic packaging, as well as a wide variety of flexible or rigid solids and semi-liquid or viscous materials. Generally, the TIM Tester 1300 can accommodate samples with high-to-medium thermal conductivity with contact pressures ranging from 10 to 550 psi (70-3800 kpa) and at sample temperature ranging from 15C to 70C.
-
Product
Gas Analyzers
-
Teledyne Analytical Instruments
Gas Analyzers by Teledyne Analytical instruments - carbon dioxide systems, gas chromatographs, hydrocarbon analyzers, infrared analyzers, moisture analyzers, nitrogen analyzers, nitrogen oxides & ammonia analyzers, oxygen analyzers, sulfur analyzers, thermal conductivity analyzers, tunable diode laser (TDL) analyzers, ultraviolet analyzers, and more
-
Product
Integrating Spheres
-
Artifex Engineering GmbH & Co. KG
We offer integrating spheres made from a special polymer suitable for the wavelength range 250nm – 2.5 µm. For longer wavelengths in the range 700nm – 20 µm, a gold coating on a rough, metallic surface is used. Since lasers in this spectral range are usually also high power, we use solid copper as a thermally conductive substrate material. By choosing the size of the integrating sphere, the overall sensitivity of the system can be adjusted. In addition, the detector is independent of inhomogeneities in power density and polarization. The detector is also independent of the incidence location and angle of the laser radiation.
-
Product
Oxygen / Nitrogen / Hydrogen Analyzer
ELEMENTRAC ONH‑p 2
-
The new ELEMENTRAC ONH-p 2 is a powerful and robust elemental analyzer for measurement of oxygen, nitrogen and hydrogen concentrations in inorganic materials like steel, iron, copper or ceramics. The highly sensitive NDIR and thermal conductivity detectors reliably detect element concentrations from low ppm content to high percentages.
-
Product
Process Thermal Conductivity Analyzer
CI-IN56
-
Shanghai ChangAi Electronic Science & Technology Co.,Ltd
CI-IN56 thermal conductivity analyzer is a kind of intelligent analyzer based on microprocessor, considering microprocessor thermal conductivity sensor as measuring unit. It has high accuracy, good stability, comprehensive function and long service life. Applied to test the H2 or He in binary gas or binary mixture gas. - See more at: http://en.ci-ele.com/dcb675d2-4e33-4eb9-33a0-60edf78c9348/6b085f77-cb25-8ccc-faaf-9b581710d730.shtml#sthash.Xs2anvsw.dpuf
-
Product
Heat Flow Meters
Fox Series
-
Fox Series Heat Flow Meters are reliable, easy-to-use, and durable thermal conductivity measurement instruments. Each of our FOX heat flow meters combines advanced technology with over 20 years of superior engineering. Explore our lineup of thermal conductivity instruments.
-
Product
Heat Flux Sensors
MF Series
-
EKO Heat Flow Sensors are applied to measure the heat flow or thermal conductivity in materials and radiative IR flux emitted by body surfaces. The sensors are suitable for indoors applications, some models made for outdoors purposes and are available in different sizes and thickness. All sensors are extremely flat, which is a big advantage considering the minimum interference with the conditions of the testing area the thermal dynamics. Since sensor foils are relatively flexible those can easy be applied on curved surfaces and can be used in different applications to measure the performance of insulating materials in refrigerators, container walls, pipes, building constructions, etc.
-
Product
40-CH 100G Thermal AWG
-
Flyin’s 40 channel 100G Thermal AWG(100G TAWG) is designed for use within the C -band release of DWDM system. To decrease the power dissipation of the devices in different environmental conditions, the TAWG package is special designed with selection of reliable thermal plastic with low thermal conduction, and the TAWG operating temperature is controlled by using foil resist heater or Peltier TEC with thermistor temperature sensor. Different input and output fibers, such as SM fibers, MM fibers and PM fiber can be selected to meet different applications. We can also offer different product packages, including special metal box and 19” 1U rackmount.
-
Product
H2 and Binary Gas Analyzers
-
PST offer a range of hydrogen (H2) and binary gas analyzers utilising the thermal conductivity property of gases to determine the concentration of a Target Gas (hydrogen for example) within a known Background Gas such as oxygen, nitrogen or argon.
-
Product
CAE Software
Femtet
-
Femtet is the simulation software based on the finite element method. It solves 8 physical phenomena (electric field, magnetic field, electromagnetism, mechanical stress, thermal conductivity, fluid, acoustic waves, and piezoelectricity). Multiphysics between the solvers are available as well. Its extensive functions include modeling, automatic meshing, and results display.
-
Product
Small size non-steady-state probe for thermal conductivity measurement
TP08
-
Hukseflux Thermal Sensors B.V.
TP08 is a probe that offers the possibility to perform a practical and fast measurement of the thermal conductivity (or thermal resistivity) of the medium in which it is inserted at a high accuracy level. It works in compliance with the ASTM D 5334-00, D 5930-97 and IEEE 442-1981 standards. The TP08 is a small version of type TP02, made for situations where the length of the TP02 poses a problem. The standard TP08 probe has proven its suitability for soils, thermal backfill materials, sediments, foodstuff, powders, sludges, paints, glues and various other materials.
-
Product
Thermal Testing
-
A view of multiple testing stations for use in conducting Thermal Analysis on various materials. This is one of several areas assigned to various thermal tests. Differential Scanning Calorimetry (DSC), Thermogravimetric Analysis (TGA), Thermomechanical Analysis (TMA), and Dynamic Mechanical Analysis (DMA)
-
Product
Diode Submounts
-
Ultra-precise patterning of thin film metals on dielectrics with high thermal conductivity are used for diode submount applications. Via the acquisition of Ion Beam Milling, Inc., SemiGen is the industry leader for laser diode submount fabrication. As each application is different, we work with customers to develop a custom design that perfectly fits their requirements. We have experience producing circuits utilizing substrates of varying thicknesses with high thermal conductivity such as alumina (Al), aluminum nitride (AlN), and beryllium oxide (BeO). SemiGen can deliver laser diode submounts with or without Au/Sn pads depending on your needs.
-
Product
Gas Analyser
LT GasAnalyzer
-
Highly performant analyzer for measuring the concentration of technical gases based on a thermal conductivity sensor, an infrared sensor a para magnetic sensor or combinations of these sensors. Sensors are precise, robust and have a low cross-sensitivity. Extractive online measurement of the concentration of flammable or non-flammable gas components in gas mixtures. Can measure trace oxygen (O2) levels in the parts per million (ppm) range.
-
Product
Light/Laser Flash Analyzers
-
Light or laser flash is a measurement technique used to determine the thermal diffusivity, thermal conductivity, and specific heat capacity of materials. Light flash measurements are essential for characterizing the heat transfer and storage properties of a variety of materials, whether the sample of interest is expected to insulate, conduct, or simply withstand temperature changes.
-
Product
Thermal Transport
-
The thermal transport probe measures thermal conductivity and thermoelectric power (defined by the Seeback Coefficient). Electrical and thermal contacts are made to opposite ends of the sample allowing for customisation to suit the sample requirements of the user.
-
Product
PXIe-4353, 32-Channel, 24-Bit PXI Temperature Input Module
781348-01
Analog Input Module
32-Channel, 24-Bit PXI Temperature Input Module—The PXIe‑4353 is a thermocouple input module that provides integrated data acquisition and signal conditioning for temperature measurements. The PXIe‑4353 includes increased accuracy and synchronization features for scalable measurement systems from low‑ to high‑channel counts. The high accuracy is attributed to the NI TB‑4353 isothermal terminal block that optimizes thermal conductivity between the thermocouple terminals and the cold-junction compensation (CJC) channels. The PXIe‑4353 has two auto zero channels for offset compensation as well as open thermocouple detection to identify disconnected thermocouples.
-
Product
Non-steady-state probe for thermal conductivity measurement
TP02
-
Hukseflux Thermal Sensors B.V.
TP02 is a probe that offers the possibility to perform a practical and fast measurement of the thermal conductivity (or thermal resistivity) of the medium in which it is inserted at the highest accuracy level. It works in compliance with the ASTM D 5334-00, D 5930-97 and IEEE 442-1981 standards. The standard TP02 probe has proven suitability in soils, thermal backfill materials, sediments, foodstuff, powders, sludges, paints, glues and various other materials. The Non-Steady-State Probe (NSSP) measurement method (also known as transient line source, thermal needle, hot needle, heat pulse- and hot wire technique) has the fundamental advantages that it is fast and absolute while the sample size is not critical. Hukseflux is specialised in NSSP design. Special models have been developed for in-situ field experiments. For permanent installation in soils, a dedicated model, TP01, is available. TP02 has been designed and tested in collaboration with the Applied Physics Group of Wageningen University.





























