Product
Solid Load Cartridges
RediSep SLC
-
RediSepsolid load cartridges from Teledyne LABS are perfect for the purification of insoluble samples. They offer the convenience of applying your sample directly to the silica bed. We offer a variety of sizes of pre-packed cartridges to give you superior flexibility in sample loading. Or, choose an empty option to fill with your own sorbent.
-
Product
500 AMP Carbon Pile Load Tester
710
-
The #710 will perform variable load testing on 12 volt batteries rated as high as 1000 Cold Cranking Amps. Use this battery tester to simulate actual cranking loads. Also tests alternator charging voltage and relative starter current draw. The #710 features large dual meters to display the battery voltage and load current simultaneously, during the test.
-
Product
Artificial Phantom Load with Power Factor
RC-50
-
The RC-50 Artificial Phantom Load has been re-designed to meet the most exacting requirements. It operates from a single phase source and will deliver current at either unity or 50% power factor at all full load ranges. Features: Artificial Load, Light Weight, 50 Amps, 50% Power Factor.
-
Product
AC Load Bank (Resistive & Inductive)
K-1000 Resistive & Inductive
-
Kongter Test & Measurement Co., Limited
Kongter resistive & inductive AC load banks are used to simulate the motor loads or other electromagnetic devices working at their rated power factor. Many backup generators and turbines are rated at 0.7, 0.8 or 0.85 power factor and need to be commissioned at nameplate capacity using a combination of resistive and reactive load to fully qualify their operating capability. Using a resistive & reactive load bank enables comprehensive testing from a single unit.
-
Product
48V / 200 Amp Load
BD12-48P
-
For Battery Discharge testing and Power Supply testing. This particular Load has been designed to operate with 48V and 50V, (24 or 25 cells at 2V each), battery systems and is extremely cost effective.
-
Product
Custom Load Banks
-
Power House Manufacturing, Inc.
Custom Load Banks are our specialty. Power House Manufacturing is dedicated to providing our customers with exactly what they need. Having years of custom load bank manufacturing experience, Power House can deliver the perfect custom testing solution you require.
-
Product
High Precision Flame-proof Compression Type Load Cell
ZR-KE
-
Flame-proof Compression Type Load Cell
-
Product
Load Cells
-
For use in harsh environments, our Models T66 (bending beam),T85 and T85-T(shear beams)are manufactured fromstainless steel, fully welded and hermetically sealed to provide total environmental protection (IP68 and IP69K). The T85-Tmodel has a blind loading hole, ideal for use in platform scales.
-
Product
Phantom Load Test Set
-
Is a testing accessory, wisely designed for field testing service. This equipment helps in providing artificial load that is unaltered by the change in power supply.
-
Product
Load Cell Indicators
-
Procter & Chester Measurements Ltd
The instrumentation will power the load cell. The mV/V signal coming back from the load cell is converted by the indicator and displays the force in a unit (e.g.: Kg, kN, lb – customers choice). The indicators within this range are encased so that the operator can either use it on the move (if battery powered) or be a permanent fixture, e.g.: wall mounted.
-
Product
Spring Loaded LVDT Position Sensors
-
Gage head LVDTs are ideal for industrial environments requiring a reliable and rugged sensor. With near infinite resolution and excellent repeatability, these spring-loaded LVDTs are ideal for quality testing and gaging with several customization options available.
-
Product
Small Telemetry Compressive Load Cell
TC-3.0-SM
-
DLM’s Telemetry Compressive Load Cells can be used independently or in combination as part of weighing platforms.
-
Product
Programmable DC Electronic Load
-
Programmable DC electronic load is a device that precisely regulates the load voltage and current dissipation power consumption of electrical energy. There are several important parameters to consider when choosing programmable DC electronic load, including maximum power, maximum current, maximum voltage, current slope, and so on. Each indicator is related to the needs and applications we actually test.
-
Product
AC Load Banks
XL500-XL600 Series
-
Mosebach Manufacturing Company
The XL500-XL600 Series load banks offer you a continuous load at various voltages in a compact, lightweight enclosure.
-
Product
THRU HOLEBARE AND LOADED BOARD TEST PROBES
SERIES 93
-
ElectricalMAXIMUM CURRENT: 7 amps continuousat working travel, non-inductiveRESISTANCE: At 35 mA test current,35 mOHMS mean
-
Product
DC Electronic Load
3310F Series
-
Each 3310F Series module has its own control and display panel, CC/CR/CV/CP/Dynamic modes, plug in 3300F with 150 sets Store/Recall memory which provides load set-up more efficiently,also can be controlled intranet via RS232、Ethernet、USB and GPIB interface.
-
Product
LV Iron Core Line & Load Reactors
-
Line and load reactors are generally serial-connected to the input and/or output terminals of three phase equipment such as motor speed controllers, inverters and UPS systems. These equipment make use of semiconductor switches such as IGBTs, thyristors, and diodes and therefore create harmonic distortion and high switching over-voltages (dv/dt). Use of such equipment has been becoming more widespread as the technology advances. However, the negative effects of these equipment should not be overlooked.
-
Product
Refrigerator Freezing Tester M Load Test Package
CX-MP
-
Shenzhen Chuangxin Instruments Co., Ltd.
The freezing load test package is made according to GB/T8059.2 GB/T8059.4, and we can also make the package in different standard according to different requirement.
-
Product
Digital LOOP/PSC/LOAD Tester
1825 LP
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures the voltage drop as if 16A was flowing between Line and Neutral.● Displays voltage without current (V at 0A).● Display voltage as if 16A flowing between Line and Neutral (V at 16A).● Loop test for L-E● PSC between L-N.● Single one smart push button operation; ON, Scroll through results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software range).● Combined prospective short circuit current, loop and load tester.● Display can be customized for large orders.
-
Product
DC Electronic Load
-
Siglent SDL1000X series Programmable DC Electronic Load features an input range up to 150V/30A/300W. CC Dynamic mode frequency is up to 25 kHz. It delivers stability over a wide range of applications and can meet all kinds of testing requirements including: Power, battery/handheld device design, industry, LED lighting, automotive electronics, and aerospace.
-
Product
Load Testing Services
-
If you're looking for load testing services, you're probably investing heavily in advertising campaigns. But unless you run load tests to ensure your system works properly under real-life load conditions, you can lose both your marketing dollars and potential sales. With UTOR you get the confidence that your application will not damage your business.
-
Product
Programmable DC Electronic Load
IT8500+ Series
-
IT8500+series (150W~3000W) single-channel programmable DC electronic loads are designed for middle & high-end applications. They can be offered as multiple solutions according to customer's design and testing requirements.
-
Product
Bottle Vertical Load Testers
-
Bottle Vertical Load Tester measures the vertical load strength of glass containers, simulating capping and stacking loads.
-
Product
XR Resistive Reactive Load Banks
-
Mosebach Manufacturing Company
Mosebach’s XR series load bank offers you a range of options for resistive reactive loads in both lower voltages of 480 and 600 or MV at 4160 and higher. Outdoor rated user friendly for years of use.
-
Product
Generator Loading System
-
Mosebach Manufacturing Company
GLS (Generator Loading System) is a load bank for use with your generator to load it automatically to your set point. This will keep your generator running at its optimal point and reduce your maintenance costs. Fully programmable by you.
-
Product
Inductive Load Tester
4602-LV
-
There is a tendency that MOSFET has Low On Resistance so that it demands that Inductive Load Tester to have higher forcing current for measurement. The forcing current is limited by forcing voltage with previous test method. Thus it becomes difficult to test this kind of middle power range devices.