Electro-Chemical
chemical action when combined with electricity.
-
Product
Scanning Electro-chemical Microscope
920D
-
The scanning electrochemical microscope (SECM) was introduced in 19891 as an instrument that could examine chemistry at high resolution near interfaces. By detecting reactions that occur at a small electrode (the tip) as it is scanned in close proximity to a surface, the SECM can be employed to obtain chemical reactivity images of surfaces and quantitative measurements of reaction rates.
-
Product
Multiplexer
-
The Ivium Technologies electrochemical multiplexer can work individual cells with 2, 3 and 4 electrodes and a WE2 (BipotentioStat, optional). Each multiplexer has 8 channels and the multiplexer units can be stacked so that up to 64 channels can be controlled sequentially by a single potentiostat.
-
Product
DS Sensor
Z-Gard DS Sensor
-
The Z-Gard DS Sensor is designed to detect the presence of carbon monoxide and nitrogen dioxide gases in parking garages, vehicle storage areas or wherever else these two toxic gases could be found. These sensors employ electrochemical sensors which generate a representative output signal proportional to the calibrated operating range.
-
Product
Electrochemical Analyzer
EC Epsilon EClipse
-
The Epsilon EClipse™ is the latest electrochemical analyzer manufactured by BASi. It is a potentiostat/galvanostat with a second working electrode for bipotentiostat measurements. It comes with software that enables the most popular electrochemical techniques such as cyclic voltammetry, chronoamperometry, and chronopotentiometry (select Techniques below for a more complete list). The Basic Plus software can be purchased to enable pulsed voltammetry and stripping voltammetry techniques.
-
Product
SUGGESTED REPLACEMENT/UPGRADE C165+*
C165
-
UEi Test & Measurement Instruments
The C165 Combustion Analyzer with EOS Technology and High Altitude Compensation eliminates the number one hassle experienced by HVAC contractors, the cost and down time of replacing the O2 sensor. The EOS technology for combustion analysis replaces the everyday electro-chemical O2 sensor with the EOS technology CO2 sensor lowering the cost of ownership and includes High Altitude Compensation
-
Product
Reference Electrodes
-
Reference electrodes are widely used as: electrochemical measurements (CV, LSV, DPV, etc.) electrochemical devices (detectors for HPLC, biosensor, etc.)
-
Product
Continuous LPR Corrosion Meter
MS2001L
-
The MS2001L is a microprocessor-based, field-mountable corrosion rate meter. This versatile instrument measures the instantaneous corrosion rate and electrochemical current between the electrodes of any standard 2-electrode linear polarization resistance (LPR) probe. Corrosion rate is displayed on the LCD display.
-
Product
Localized Electrochemical Impedance Spectroscopy
VS-LEIS
-
The VersaSTAT 3F applies an AC voltage to the sample emerged in electrolyte. This "global" voltage generates AC current to flow at the electrode / electrolyte interface. A dual-element probe is positioned in solution close to the surface of the sample. The electrometer measures a differential voltage measure between the two measurement elements as a measure of local voltage-drop in solution. This voltage-drop exists in solution because of current flow from local reactions at the sample, the resistance of the electrolyte and the spatial separation of the dual measurement elements.
-
Product
Scanning Electrochemical Microscope
VS-SECM (DC And AC)
-
The SECM integrates a positioning system, a bipotentiostat, and an ultramicroelectrode probe or tip. The positioning system moves the probe close to the surface of the sample, within the local imaging zone. The bipotentiostat can polarize the probe only (feedback mode) or the sample and the probe independently (generator-collector mode), while measuring the resulting current(s). The probe is specially designed to have a specific tapered polish (per the RG ratio) and active radius below 100 microns. The positioning system scans the probe and charts position with measured electrochemical parameters, creating a data map of local current.
-
Product
CellTest Multichannel Potentiostat
-
Simultaneous Electrochemical Impedance Spectroscopy (EIS) tests can be run on multiple cells by connecting Solartron 1455A/1451A series frequency response analyzer (FRA) modules to the 1470E. These FRAs can operate in single sine correlation or multi-sine / Fast Fourier Transform (FFT) analysis mode, providing the ultimate in speed, precision and accuracy. The 1455A FRA provides high performance impedance measurements over the frequency range 10 μHz to 1 MHz, while the 1451A FRA operates from 10 μHz to 100 kHz.
-
Product
Electrical Resistance (ER) Monitoring
-
The electrical resistance (ER) technique is an "on-line" method of monitoring the rate of corrosion and the extent of total metal loss for any metallic equipment or structure. The ER technique measures the effects of both the electrochemical and the mechanical components of corrosion such as erosion or cavitation. It is the only on-line, instrumented technique applicable to virtually all types of corrosive environments.
-
Product
Linear Polarization Resistance (LPR) Monitoring
-
The electrochemical technique, commonly referred to as Linear Polarization Resistance, is the only corrosion monitoring method that allows corrosion rates to be measured directly, in real time. Although limited to electrolytically conducting liquids, the response time and data quality of this technique make it clearly superior, where applicable, to all other forms of corrosion monitoring.
-
Product
Potentiostat Galvanostat
PARSTAT 4000A
-
The PARSTAT 4000A stands alone in its ability to deliver high compliance voltage and wide dynamic current range, as standard, to cover a range of applications. The PARSTAT 4000A builds on PAR's history as the world-leader in DC electrochemical measurements and takes advantage of a common R/D team with Solartron Analytical, the world-leader in Frequency Response Analyzer (FRA) technology, to provide a best-in-class complete system.
-
Product
Chloride Test System
C-CL-2000
-
The C-CL-2000 produces results on-site, within minutes that are accurate and comparable to expensive laboratory tests. It measures the electrochemical reaction of a weighted sample placed in an extraction liquid. It automatically shows a temperature compensated reading of percent of chlorides on its digital display. A wide range - from 0.002 to 2% chloride by weight - is covered.
-
Product
Electrochemical Analyzer/Workstation
600E
-
The Model 600D series is designed for general purpose electrochemical measurements. The figure below shows the block diagram of the instrument. The system contains a fast digital function generator, high speed data acquisition circuitry, potentiostat, and a galvanostat (available only in select models).
-
Product
Percent Oxygen Sensors
-
At Process Sensing Technologies (PST), we offer replacement electrochemical oxygen sensors compatible with major fixed and portable oxygen analyzers in challenging industrial environments. Tailor your solution with our versatile housing options, allowing you to specify either a 2-ring or connector design.
-
Product
Solid Pins
-
Advanced Probing Systems, Inc.
APS produces electro-chemically machined pins in diameters between .020"-.040" in a variety of materials for use in various applications. These “large diameter pins” are used in various medical applications, industrial applications, board testing, LED & LCD test and as components in small tools. APS’s design services can help you select the optimal material from tungsten, beryllium-copper, Paliney 7® or various stainless steel alloys or work with the material of your choice. Pins can be produced with either a sharp or radius (rounded) tip. Tapers can be highly polished, slightly polished, matte or neutral in finish.
-
Product
Single Channel Potentiostats
12XX Series
-
The 12xx Series Potentiostats has two current models: the 1287A and 1280Z. This family of potentiostats communicate through trusted GPIB interface technology that can convert to USB for easy connection modern computers. The Solartron Analytical 1287A and 1280Z are often driven by CorrWare software for DC testing, such as Cyclic Voltammetry, and ZPLOT for AC testing, such as Electrochemical Impedance Spectroscopy.
-
Product
Potentiostat Galvanostat
1287A
-
The Solartron Analytical 1287A potentiostat and galvanostat is a high accuracy, wide bandwidth instrument which offers a range of DC test capabilities. The 1287A can be coupled with a frequency response analyzer, such as the Solartron Analytical 1260A or 1255B, and ZPLOT software for AC tests such as Electrochemical Impedance Spectroscopy.
-
Product
PowerNet Tester
-
The PowerNet Tester (BNT) is designed to test batteries, ultracaps and all other types of electrochemical power sources for 14 V and 42 V power net systems. Designed to test vehicle system batteries for 14V and 42V power net systems. But they may also be used for testing all other types of electrochemical power sources just by setting the required current and voltage values.
-
Product
Handheld Electrochemical Battery Analyzer
EC-Series
-
Global Energy Innovations, Inc.
The EC1000™ and EC2000™ are the only handheld, Multi-Frequency, ElectroChemical Battery Analyzers on the market using CELScan™ technology. This means they can report both the Electrical (Impedance & Voltage) and Chemical (Sulfation and Dryout) properties of lead acid batteries (VLA, VRLA, GEL). Other battery types (NiCd, NiMH, Lithium-Ion and others) may also be tested using the EC1000™ and EC2000™.
-
Product
Surface Insulation Resistance Testing
AutoSIR2™
-
One AutoSIR chassis can hold between 1 to 16 measurement cards and can monitor up to 256 x 2-point test patterns or 78 x 5-point test patterns, or 32 x 9-point test patterns at selectable intervals from minutes to days. Each channel is current limited (1 M Ω), ensuring that dendrites are preserved for failure analysis. The frequent monitoring capability provides a full picture of the electrochemical reactions taking place on a circuit assembly, and provides early trend analysis enabling tests to be curtailed, thus saving considerable test time and money.
-
Product
Radiometer Analytical Probes
-
Radiometer Analytical develops and manufactures an extensive range of electrochemical electrodes - combined pH, glass or reference electrodes, metal electrodes, ion-selective electrodes and conductivity cells - for every application and budget.
-
Product
Electrochemistry Research Equipment
-
Our electrochemical equipment will help your group achieve laboratory and research goals. The best-selling EZstat Pro potentiostat/galvanostat can run cyclic voltammetry, electrochemical impedance spectroscopy (EIS), battery tests, and high speed galvanostatic intermittent titration technique (GITT). The EZstat HV potentiostat delivers up to 1 amp at 25 volts. The Powerstat comes in two configurations (5 amp vs 20 amp). The Duostat bipotentiostat can operate rotating ring-disk electrode experiments. The Arraystat and ArrayPGstat feature multichannel operation with different customizable options (current range, number of channels, etc.).
-
Product
Weld Testers
-
The Weld Tester is our most versatile electrochemical monitoring instrument. Housed in a substantial metal case with brushed anodised aluminium front panel and green military specification connectors this equipment looks functional and professional. The top row of connectors are exactly the same as provided on a Gill 12 whilst the bottom row are for the additional weld segments. Using the same Potentiostat, Galvanostat, Zero Resistance Ammeter with integrated Frequency Response Analyser and Sweep Generator as a Gill 12 allows all the tests supplied with the Gill 12 to be supplied with the Weld Tester.
-
Product
Transmitter Monitors Carbon Monoxide
CO-R
-
The CO transmitter monitors carbon monoxide (CO) levels and is designed for the continuous monitoring of vehicle exhaust in non-hazardous areas. The CO uses a wide spectrum, long life electrochemical sensor to measure the amount of carbon monoxide in the environment. It is offered with an operating range of 0 to 125 ppm. Both the Room and Duct CO transmitters are offered in a standard NEMA 1 rated ABS Polycarbonate plastic enclosure. An optional NEMA 4X watertight and dust proof enclosure is only available with the CO room transmitter.
-
Product
Carbon Monoxide Detector, CO
ENVIROMUX-CMD
-
Continuous air monitoring. Pre-set alarm points alert at: 70 ppm after 60 to 240 minutes; 150 ppm after 10 to 50 minutes; and 400 ppm after 4 to 15 minutes. Flush or surface mount. Test functionality of electrochemical CO sensing cell. Connect to RJ45 or digital input sensor ports. Screw terminal. To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal. Maximum cable length: 1000 ft (305m). LED indicators for operation status and system test. Powered by ENVIROMUX-2D/5D/16D. Regulatory approvals: UL.
-
Product
Power Potentiostat/Galvanostat
1100C
-
The Model 1100B series power potentiostat/galvanostat is designed for electrochemical applications that require relatively large current and high compliance voltage, such as battery studies, corrosion, electrolysis, and electroplating. The current range is 2 A, and the compliance voltage is 25 V. The instrument contains a high speed digital function generator, a fast data acquisition system, filters for current signals, iR compensation circuitry, a potentiostat, and a galvanostat (Model 1140B). The potential control range is 10 V.
-
Product
Industrial Oxygen Transmitters with Zirconia or Electrochemical Sensors
-
The range of Oxygen Transmitters from PST are compact and robust devices that utilise zirconia, solid state ceramic or electrochemical sensing technologies to give a reliable measurement of oxygen concentration.





























