Differential Probes
Measure signals that are not ground referenced.
-
Product
Active Differential Probe, 100 kHz to 12 GHz
U1818B
High Frequency Probe
The Keysight U1818B 100 kHz to 12 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818B allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
Product
ProBus Probe Adapter for TekProbe-BNC Probes
TPA10
-
- Allows TekProbe interface level II probes to work with any ProBus-equipped Teledyne LeCroy oscilloscope- Automatic probe detection- Provides all necessary power and offset control to the attached probe- Supports probes up to 4 GHz- Easy firmware updates- Wide variety of probes supported including: Preamplifiers, Current Probes, Single-Ended Active Probes and Differential Active Probes
-
Product
InfiniiMax Probe, 7 GHz
1134B
Oscilloscope Probe
Use for high-speed differential or single-ended probing in embedded designs
-
Product
Acute High Voltage Differential Probe, 10x/100x, 100MHz, 700V
ADP1100
-
*USB Powered (or Power Bank)*Bandwidth up to 10 MHz*Overrange Indicator*Audible Overrange Alarm*Bandwidth Limit : 5 MHz / Full*Can be used by any DSO which has the USB port(s).*EC Declaration: EN 61010-031:2002 +A1:2008*Double-layer wire for power insulation
-
Product
Small IC Adapter for ZD Differential Probe Qty 2
PACC-ZD006
-
Small IC adapter for ZD differential probeQty 2
-
Product
Water Quality Sensors
-
Omega offers combination and differential probes for accurate measurement of pH, conductivity, ORP, and disolved oxygen. Submersible sensors for use in drums, open tanks and streams are available.
-
Product
Differential Probe
DP-8V
-
*MAX. Input Voltage: ±4KV DC or 8KV p-p or AC 2.8KV rms*Bandwidth: DC-50MHz*Input Impedance 20MΩ// 2PF*x10, x100, x1000 Attenuator*To Ground MAX. Voltage: 4KV CAT III*Output Impedance 50Ω
-
Product
1kV, 120 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3106A
-
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
Product
Differential Probe
-
With signals becoming faster, and power supply voltages going lower, these active differential probes will allow floating measurements from 100uVolts to as high as 7000 volts. These probes provide high CMRR and a broad frequency range.
-
Product
500 MHz Active Differential Probe
AP033
Differential Probe
Fully Integrated: With the ProBus™ interface, the AP033 becomes an integral part of the oscilloscope. The probe sensitivity and offset can be controlled from the oscilloscope front panel, the probe front panel, or by using remote control commands (GPIB or RS-232). Sensitivity, offset, input capacitance, and common mode voltage range are displayed on the oscilloscope screen. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
Product
High Voltage Differential Probes
-
A high voltage differential probe is used for measuring the voltage difference between two test points where neither test point is at ground. High voltage differential probes from Tektronix can be used for signals up to 6000 V. These probes are the best choice for making non-ground referenced, floating or isolated measurements in large part due to their common mode rejection capability. These products are designed, manufactured, and serviced by Tektronix.
-
Product
High Frequency Coaxial Analytical Probes
-
D-COAX offers four analytical probe models: HyPac model for package characterization, and two models, Omni and OmniJet, for board level characterization, and DP1.4mm differential, single-ended probe.
-
Product
High Voltage Differential Probe
ADF25A
-
Permits conventional grounded oscilloscopes to be used for the display and measurement of multiple floating signals with high common mode voltages
-
Product
Optically Isolated Measurement System
IsoVu
-
IsoVu offers complete galvanic isolation and is the industry’s first measurement solution capable of accurately resolving high bandwidth, low voltage differential signals in the presence of large common mode voltages. The stand out feature of IsoVu™ is its best in class common mode rejection across the entire bandwidth. Accurate differential measurements rely on a measurement system’s bandwidth, rise time, common mode voltage, common mode rejection capability, and the ability to connect to smaller test points to characterize devices that are shrinking in size and increasing in performance. Despite these requirements, advancements in test and measurement for power testing, EMI testing, ESD testing, and remote measurement capability have been minimal at best and have not kept pace with changing requirements. While differential voltage probes have had modest performance gains in regard to bandwidth, these probes have failed to make any substantial improvements in regard to common mode rejection, and connectivity. IsoVu is a leap forward in technology and is the only solution with the required combination of high bandwidth, high common mode voltage, and high common mode rejection to enable these differential measurements.
-
Product
NI-5191, 800 MHz, ±30 V, 10X Attenuation, Differential Active Oscilloscope Probe
781785-01
Oscilloscope
The NI-5191 is a differential, active voltage probe that offers 800 MHz of input bandwidth with a 10:1 attenuation ratio. You can use it with oscilloscopes that provide 50 Ω input impedance. You can power the probe using a Type-N barrel power connector from a USB port or using a 9 V alkaline battery.
-
Product
Differential Probe
DP-40K
-
*MAX. Input Voltage: ±20KV DC or 40KV p-p or AC 14KV rms*Bandwidth: DC-20MHz*Input Impedance 100MΩ// 1PF*x500, x5000 Attenuator*To Ground MAX. Voltage: 10KV CAT III*Output Impedance 50Ω
-
Product
DH Series Solder-In Tip, 30 GHz BW, 3.5 Vpp Range
DH-SI
-
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
Product
500 MHz 60 V Common Mode Differential Probe
DL05-HCM
Differential Probe
60 V of common mode and 80 V differential input range with 1 GHz of bandwidth, make these probes ideal for lower voltage GaN power conversion measurements. The 60 V of common mode is well suited for handling any float of the battery and bulk/absorption voltage during charging, while the 80 V differential input range provide margin for any overshoot.
-
Product
Replacement Spade Terminals for High Voltage Differential Probe
PK-HVA-05
-
Replacement Spade Terminals for High Voltage Differential Probe
-
Product
Y Lead Adapter for ZD Differential Probes Qty 1
PACC-ZD001
-
Y lead Adapter for ZD differential probes Qty 1
-
Product
Differential Probe
DP-16VF
-
*MAX. Input Voltage: ±8KV DC or 16KV p-p or AC 5.6KV rms*Bandwidth: DC-150MHz*Input Impedance 20MΩ // 5PF*X400, X4000 Attenuator*To Ground MAX. Voltage: 3.5KV CAT III*Output Impedance 50Ω
-
Product
200 MHz, 3.5 pF, 1 MOhm Active Differential probe
ZD200
-
With the ProBus interface, the ZD200 becomes an integral part of the oscilloscope. The probe sensitivity and offset are automatically optimized based on the oscilloscope gain settings, so control is transparent to the user. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
Product
700 V, 25 MHz High-Voltage Differential Probe (÷10, ÷100)
AP031
Differential Probe
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
Product
6kV, 100 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3605A
Differential Probe
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
Product
13 GHz Differential Probe with ProLink Interface
DH13-PL
-
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
Product
4 GHz ProBus2 Differential Probe with Dx20-SI Solder-In Tip
D420-A-PB2
Differential Probe
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
7kV, 100 MHz, 2.5 pF, 40 M, Rise Time < 3.5 ns, High Voltage Differential Probe
T3HVD7000-100
Differential Probe
7kV, 100 MHz, 2.5 pF, 40 M, Rise Time < 3.5 ns, High Voltage Differential Probe.
-
Product
DH Series High-Sensitivity Solder-In Tip, 30 GHz BW, 2.0 Vpp Range
DH-SI-HS
-
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
Product
Differential probe
DP3000 Series
-
A “differential” probe is an active probe which has two inputs, one positive and one negative as well as a separate ground lead and it drives a single terminated 50Ω cable to transmit its output to one oscilloscope channel
-
Product
Replacement Long Alligator Clips for High Voltage Differential Probe
PK-HVA-04
-
Replacement Long Alligator Clips for High Voltage Differential Probe