NF
1) EMF closest to the antenna. 2) Near-field optics.
-
Product
IRIG Time Code Receiver for Computers (PCI Express)
TCR180PEX-EL
-
Meinberg Funkuhren GmbH & Co. KG
The TCR180PEX-EL receives IRIG-A/B/G, IEEE 1344, IEEE C37.118 or AFNOR NF S87-500 time codes and can be used for synchronizing the system time of its host PC. The IRIG output of this card can generate an IRIG signal for other IRIG time code readers. It is used in applications like data acquisition, standalone computer time synchronization (for systems without a network connection or higher accuracy requirements).
-
Product
BF-Series Soft Stop Plus Models
-
The E-DRIV® BF-Series soft stop plus models is designed with an unique "soft-stop" shock absorbing clutch that is ideal for fastening shock sensitive components such as disk drives, plastics, and electronics. The ergonomically designed soft stop clutch reduces impact and vibration transmitted in the screw fastening process, which delivers less torque reaction to operator. The electric screwdriver offers a Double Hit Mode for soft joint applications and a selectable Soft Start mode. Designed for precision torque control the brushless motor design ensures durability and reduces the standard maintenance costs associated with brush type electric screwdrivers. The NF power tool is ESD certified, ensuring less than 1 Ohm at the bit tip. ESD management assures product quality, cost savings and a reduction in overall ESD failures.
-
Product
RF Near Field Probe Set DC to 9GHz
-
EMF & RF close field sniffer-set for use with any Spectrum Analyzer or Measurement Receiver. The EMC Near Field probe set allows for straightforward pinpointing and measurement of interference sources in electronic component groups as well as execution and monitoring of generic EMC measurement. Our RF near field probe set is especially suitable for: - Pinpointing interference sources - Estimation of interference field strength - Verification of shielding and filtering measures - Identifying faulty components - Detecting circuitry overly sensitive to interference.
-
Product
Ka-Band Silicon 5G Quad Core IC
AWMF-0108
-
The AWMF-0108 is a highly integrated silicon quad core IC intended for 5G phased array applications. The device supports four Tx/Rx radiating elements, includes 5 bit phase and 5 bit gain control for analog RF beam steering, and operates in half duplex fashion to enable a single antenna to support both Tx and Rx operation. The device provides 26 dB gain and +9 dBm output power during transmit mode and 28 dB coherent gain, 5.0 dB NF, and -28 dBm IIP3 during receive mode. Additional features include gain compensation over temperature, temperature reporting, Tx power telemetry, and fast beam switching using eight on-chip beam weight storage registers. The device features ESD protection on all pins, operates from a +1.8 V supply, and is packaged in a 48 lead 6x6 mm QFN for easy installation in planar phased array antennas.
-
Product
USB Magnetometer
-
MultiDimension Technology Co.,Ltd.
A three-axis digital magnetometer that is intended for the measurement of magnetic fields near the probe tip at frequencies less than 250 Hz.
-
Product
CATV Booster Optical Amplifier
HA5100
-
Hangzhou Huatai Optic Tech. Co., Ltd.
Huatai HA5100 series is a CATV booster optical amplifier with gain spectrum band within 1540~1563nm. This kind of optical amplifier is designed for the application of single channel or 1~8 continuous ribbon channels (ITU wavelength). Generally, fiber CATV system operates in single wavelength that has no strict requirement on gain flatness. HA5100 booster amplifier is featured with low NF, high-saturated output power. It is applicable for central bureau, sub-bureau and line relay, as well as other optical communication network. HA5100 is applied most commonly and widely compared with other optical amplifier in CATV system.
-
Product
Near Field Probes 30 MHz - 6 GHz
XF Family
-
The XF family consists of 4 passive magnetic field probes and 3 passive E field probes designed for measuring magnetic and E-fields in ranges from 30 MHz to 6 GHz during the development phase. Due to their integrated impendance matching the probes are less sensitive in the lower frequency range than the RF type probes.
-
Product
NF-SM 50 N-Female to SMA-Male Adapter
-
NF-SM 50 Adapter, N-Female to SMA-Male, Frequency Range: DC to 18 GHz, Impedance: 50 Ohm
-
Product
Near Field Moving Detector Goniophotometer
LSG-1900B
-
LSG-1900B Goniophotometer is near field Type C automatic goniophotometric instrument for luminous intensity distribution measurement. The LSG-1900B uses a constant temperature detector. It is for industrial laboratory photometric data measurements of small luminaires, such as down light, bulb light, etc.
-
Product
C & L-Band Separate Raman Fiber Amplifier
RFA7000
-
Hangzhou Huatai Optic Tech. Co., Ltd.
1. Erbium-doped Fiber Amplifier, due to the multiple cascades and the accumulation of noise caused by spontaneous emission, will reduce the system CNR greatly and thus it will limit the transmission capacity and distance of the system. Raman Fiber Amplifier (RFA) is a newly designed fiber amplifier based on Stimulated Raman Scattering (SRS) effect. It is considered as the core technology of new generation DWDM fiber over-long communication. Compared with Erbium-Doped Fiber Amplifier, Raman amplifier has the advantage of low Noise Figure (NF), wider gain bandwidth, flexible gain spectral region and stable temperature. It is the only device that can operate in 1300~1600 nm.
-
Product
Near-Field Scanning Optical Microscope Platform
MoScan-F
-
MoScan-F is a device that enables you to get the best up-to-date available spatial optical resolution using the near field scanning optical microscope (NSOM) principle
-
Product
GO-R5000 Full-Field Speed Goniophotometer
-
Hangzhou Everfine Photo-E-Info Co., LTD
The GO-R5000 integrates more powerful functions such as near field, middle field and far field distribution goniophotometer, which can be used for spatial luminous intensity distribution and total luminous flux test of indoor lighting lamps, floodlights, street lamps, etc. Equipped with imaging luminance meter and spectroradiometer, it can measure the spatial luminance distribution and spatial spectral color distribution of the light source.
-
Product
Light Engines
-
Delivering the highest brightness and optical power available, our light engines provide optimized output solutions for a range of applications such as light guide and fiber optic coupling, fluorescence excitation, and unrivaled uniform near and far field illumination.
-
Product
Scanner Probe
RFS set
-
The RFS set consits of three passive near field probes designed for the use in a measurement scanner during the development of E-field and magnetic field. They are designed for frequency ranges of 30 MHz to 3 GHz. The probe heads of the RFS set allow for close measurements needed to correctly localize interference sources on an electronic assembly. They document the whole image of the device under test`s near field. The scanner probes have a sheath current attenuation and are electrically shielded. They are connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance. The measuring signal can be increased with PA 203 or PA 303 preamplifier. On request RFS, LFS and XFS scanner probes can be produced.
-
Product
NF-SF 50 N-Female to SMA-Female Adapter
-
NF-SF 50 Adapter, N-Female to SMA-Female, Frequency Range: DC to 18 GHz, Impedance: 50 Ohm
-
Product
X-Band Silicon Radar Quad Core IC
AWS-0101
-
The AWS-0101 is a highly integrated silicon quad core IC intended for radar and 5G phased array applications. The device supports four radiating elements, single beam transmit, and dual beam receive and includes all requisite beam steering controls for 6 bit phase and gain control. The device provides 21 dB gain during transmit mode, +15 dBm output power during transmit, and 3.4 dB NF during receive. Additional features include gain compensation over temperature, temperature reporting, and fast beam switching using eight on-chip beam weight storage registers. The device features ESD protection on all pins, operates from a +1.8V supply, and is packaged in a 56 lead 7x7 QFN for easy installation in planar phased array antennas.
-
Product
CATV Separate Raman Amplifier
RFA4000
-
Hangzhou Huatai Optic Tech. Co., Ltd.
1. Erbium-doped Fiber Amplifier, due to the multiple cascades and the accumulation of noise caused by spontaneous emission, will reduce the system CNR greatly and thus it will limit the transmission capacity and distance of the system. Raman Amplifier is a newly designed fiber amplifier based on Stimulated Raman Scattering (SRS) effect. Raman amplifier is considered as the core technology of new generation DWDM fiber over-long communication. Compared with Erbium-Doped Fiber Amplifier, Raman amplifier has the advantage of low Noise Figure (NF), wider gain bandwidth, flexible gain spectral region and stable temperature. It is the only device that can operate in 1300~1600 nm.
-
Product
L-Band Separate Raman Fiber Amplifier
RFA6000
-
Hangzhou Huatai Optic Tech. Co., Ltd.
1. Erbium-doped Fiber Amplifier, due to the multiple cascades and the accumulation of noise caused by spontaneous emission, will reduce the system CNR greatly and thus it will limit the transmission capacity and distance of the system. Raman Fiber Amplifier (RFA) is a newly designed fiber amplifier based on Stimulated Raman Scattering (SRS) effect. It is considered as the core technology of new generation DWDM fiber over-long communication. Compared with Erbium-Doped Fiber Amplifier, Raman amplifier has the advantage of low Noise Figure (NF), wider gain bandwidth, flexible gain spectral region and stable temperature. It is the only device that can operate in 1300~1600 nm.
-
Product
Impedance Analyzers
-
A/D converted input signals undergo discrete Fourier transform (DFT) to calculate complex impedance values and obtain parameters and characteristics specific to the DUT, such as its capacitance, inductance and quality factor. Original NF algorithms are also applied to allow equivalent circuits made up of R, L and C along with the constants for those circuits to be estimated from the complex impedance spectrum obtained by sweeping the frequencies.
-
Product
E-DRIV® Brushless Electric Screwdrivers
NF-Series
-
Designed for high production environments, the E-DRIV® NF-Series feature a high performance brushless motor design that provides durability and reduces the common maintenance costs associated brush type electric screwdrivers. The NF tool is ESD certified, ensuring less than 1 Ohm at the bit tip. ESD management in power tools ensures product quality, cost savings and a reduction in overall ESD failures. The versatile assembly power tool is available in four different model configurations to meet the demand of various unique fastening applications.
-
Product
Near-Field Detection Module for Imaging
Transmission
-
Detection optimized for high performance near-field imaging in transmission-modeEnables optical amplitude and phase resolved near field measurementsPatented background-free detection technologyEnables bottom-side (transmission-mode) sample illumination with broadband mirrorSuited for visible and infrared wavelength range 0.5 20 mRequires transparent sample substrateMotorized parabolic mirror for easy beam-alignment in transmission-modeStationary focal point with respect to AFM-tipVariable illumination spot size (ca. 2m 100m)Suitable for plane-wave illuminationSupported AFM scan-speed: up to 20 m/s @ highest spatial resolution
-
Product
VLF Diagnostics System
PHG 70 TD
-
Cable testing and diagnostics with the BAUR PHG 70 TD. The combination of the PHG 70 programmable test generator with the BAUR dissipation factor measurement system produces the cable testing and diagnostics system PHG TD. It is operated via PC control. Dissipation factor measurement and diagnostic testing sequences can be programmed in the menu, after which the dissipation factor measured values are automatically determined in various voltage steps and a final evaluation is conducted.* Biggest dynamic range of tan delta measured values from 1 to 10-4 with a cable capacitance >10 nF to 20 uF* High resolution +/- 1x10-5 applicable even in new PE/XLPE cables* Insensitive against interferences due to complete mains separation* Lowest time required for assessing a medium-voltage cable (3-phase approx. 1 hour)
-
Product
Emissions Test System
PC-114
-
Perform Radiated & Conducted EMI pre-compliance testing at your facility up to 1 GHz. Com-Power PC-114 EMI emissions test system is a ideal solution performing pre-compliance EMC testing from 9 kHz - 1 GHz.. It has essential equipment needed for radiated and conducted EMI emissions measurements. The system includes a spectrum analyzer, antennas, near field probes, a preamplifier, LISN and a non conductive antenna tripod. Pre-compliance testing in EMC is a commonly used term not easy to define. In general, it implies testing done prior to formal testing for legal compliance. Formal legal compliance is performed at a facility designed and equipped with test instrumentation that is fully compliant with the applicable EMC standards. Such facility and instrumentation is capital intensive and can be expensive even to rent and not easily available. Compliance testing is performed per exacting requirements of the Standards and other reference documents adhering to the test methods and last detail. In addition, the test facility may require to be accredited by an accreditation body such as NVLAP, A2LA. Often it is desirable to know prior to compliance testing at such facility, whether a product is close to compliance and also how close. Pre-compliance testing is specially useful for specifications such as FCC, Part 15, EN 55022 or EN 55011 (CISPR 22 or CISPR11). Pre-compliance testing usually means using the full compliance methods but making a few educated compromises in use of site or equipment to reduce costs and testing time. Here are some benefits of pre-compliance testing.
-
Product
Near Field Probes
-
Anteral has extensive background in the design of Near Field Probes (open ended waveguides probes). Our Near Field Probes are currently being used in several laboratories around the world including the ESA's anechoic chamber. Anteral designs Near Field Probes from 10 GHz to 750 GHz covering the sectors requirements. Moreover, our Near Field Probes have a sharped design minimize reflections.
-
Product
X-Band Silicon Radar Quad Core IC
AWS-0104
-
The AWS-0104 is a highly integrated silicon quad core IC intended for radar and 5G phased array applications. The device supports four radiating elements, single beam transmit, and single beam receive and includes all requisite beam steering controls for 6 bit phase and gain control. The device provides 21 dB gain during transmit mode, 21dB gain in receive mode, +15 dBm output power during transmit, and 3.4 dB NF during receive. Additional features include gain compensation over temperature, temperature reporting, and fast beam switching using eight on-chip beam weight storage registers. The device features ESD protection on all pins, operates from a +1.8V supply, and is packaged in a 56 lead 7x7 QFN for easy installation in planar phased array antennas.
-
Product
Plane Wave Converter
PWC200
-
The R&S®PWC200 Plane Wave Converter is a bidirectional array of 156 wideband Vivaldi antennas placed in the radiating near field of the device under test (DUT). The phased antenna array can form planar waves inside a specified quiet zone within the radiating near field of the 5G massive MIMO base station for realtime radiated power and transceiver measurements (EVM, ACLR, SEM, etc.).
-
Product
Near Field Probes 30 MHz up to 3 GHz
RF2 set
-
The RF2 near field probe set consists of 4 passive near field probes for measurements in the development phase of the magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF2 set allow the step by step localization of interference sources of the RF magnetic field on assemblies. From greater distances the electromagnetic interference can be detected by RF-R 400-1 and RF-R 50-1 probes. The RF-B 3-2 and RF-U 5-2 probes with their higher resolution can more precisely detect the interference sources. Field orientation and field distribution on an electronic assembly can be detected through a trained special use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.
-
Product
IRIG Time Code Receiver & Generator for Computers (PCI Express)
TCR180PEX
-
Meinberg Funkuhren GmbH & Co. KG
The TCR180PEX receives IRIG-A/B/G, IEEE 1344, IEEE C37.118 or AFNOR NF S87-500 time codes and can be used for synchronizing the system time of its host PC. The IRIG output of this card can generate an IRIG signal for other IRIG time code readers. The output format is independent from the incoming IRIG signal - a perfect solution to your IRIG conversion requirements. It is used in applications like data acquisition, standalone computer time synchronization (for systems without a network connection or higher accuracy requirements) or as an IRIG converter device.
-
Product
Near Field Micro Probe ICR HV H Field
-
The measurement coil is located vertically in the probe head. The near field probes are run with a positioning system (Langer Scanner).
-
Product
Hybrid Raman/Er-doped Fiber Amplifier
HFA5000
-
Hangzhou Huatai Optic Tech. Co., Ltd.
1. Erbium-doped Fiber Amplifier, due to multiple cascades and the accumulation of noise caused by spontaneous emission, will reduce the system CNR greatly and thus it will limit the transmission capacity and distance of the system. Raman Fiber Amplifier (RFA) is a newly designed fiber amplifier based on Stimulated Raman Scattering (SRS) effect. It is considered as the core technology of new generation DWDM fiber over-long communication. Compared with Erbium-Doped Fiber Amplifier, Raman amplifier has the advantage of low Noise Figure (NF), wider gain bandwidth, flexible gain spectral region and stable temperature. It is the only device that can operate in 1300~1600nm.