InGaAs
Indium gallium arsenide
-
Product
Ultrafast Joulemeter
-
Measure every pulse at up to 200 kHz with MACH 6. Measure with 12-bit digital accuracy and capture up to 4 million pulses in real time. Our MACH 6 Joulemeter is the only instrument in the world that performs at this speed, and with this precision. It is designed to support our full complement of fast energy probes that include Silicon, InGaAs and Pyroelectric Detectors. Measure from pJ to mJ and from 0.35 to 2.5 m. Using the M6-Si detector and the M5-UC-QED accessory, you can make relative measurements at 266 nm.
-
Product
Automated Fibre Loss Test Set
LTS-1500
-
The LTS-1500 is a small, rugged automated fiber optic loss test set that characterises singlemode fiber links at wavelengths of 1310, 1490 and 1550 nm. It is comprised of a sensitive InGaAs based optical power meter calibrated at six wavelengths with better than -75 dBm noise level plus a stabilised laser light source with up to three selectable wavelengths.
-
Product
Bi-Directional-Coaxial LD/PD Module
BiDi-C1000 (CWDM)
-
Hangzhou Huatai Optic Tech. Co., Ltd.
*Tx Laser wavelengths optical : 17 CWDM *Using DFB Lasers *DFB laser optical: with isolation or without isolation *Low threshold current and operating current* High output power *Built-in InGaAsP monitor PD* High responsivity, InGaAs planar PIN detector *Wide temperature range operation(Tc=-40℃to+85℃) *Fiber ITU-T G.657 Bending low loss, fiber optic cable features
-
Product
O/E Converter
TIA-4000
-
The TIA-4000 is comprised of a fibre coupled InGaAs APD detector combined with a variable reverse bias voltage network and fast transimpedance amplifier. The output of the unit is brought out to a type K female SMA connector. Light falling on the detector generates a positive-going proportional current. This current, multiplied by the transimpedance produces a voltage that is proportional to the light incident on the detector surface.
-
Product
Scanning Slit Beam Profilers
-
DataRay manufactures two types of scanning slit beam profilers: the patented BeamMap series, which offers real-time M², divergence, focus and alignment management, and the Beam’R series which provides affordable, compact, and precise beam profiling. All of our scanning slit beam profilers are available with Si, Ge, and InGaAs detectors, covering wavelengths from 190 nm to 2500 nm.
-
Product
InGaAs Optical Power Head
81624C
-
The new 81624C optical power head provides a 5 mm detector area and allows flexible placement of the remote optical power meter, which is then connected to the N7749C. The 81624C accepts parallel beams with up to 4 mm diameter, standard SM fiber and MM fiber with max. 100 μm core diameter, NA ≤ 0.3. A wide choice of adapters allows input from popular fiber connector types, bare fibers or open beams. The magnetic D-shaped adapters allow rapid removal and replacement without twisting attached fibers.
-
Product
Small Footprint NIR Spectrometer
PGS Series
-
ZEISS PGS modules with a spectral coverage of 960 - 2200 nm are among the market leading NIR spectrometers, providing a small footprint, highest throughput and excellent SNR. Special TE-cooled/uncooled InGaAs detectors ensure lowest noise conditions.
-
Product
Small, Uncooled InGaAs line-scan camera with rectangular pixels
Lynx R Series
-
The Lynx R series, based on an in-house developed linear InGaAs detector, is a high-performance short-wave infrared (SWIR) camera providing high speed and quality line-scan imaging.The Lynx R cameras are able to image line rates up to 40 kHz, for demanding spectroscopy applications.The camera comes with an industry standard CameraLink or GigE Vision interface.Benefits & Features• High speed line-scan imaging up to 40 kHz (10 kHz for the 2048)• High resolution 1024/2048 Rectangular pixels option (12.5μm x 250μm)• CameraLink or GigE Vision interfacing
-
Product
Shortwave Infrared Camera Core
Tau® SWIR
-
FLIR Tau® SWIR provides outstanding short-wave infrared image quality and performance over a wide range of imaging and light level conditions. It is the ideal OEM SWIR imaging module for applications like hyperspectral instrumentation, silicon inspection, electro-optical payloads, art restoration, and portable imaging. The Tau SWIR camera incorporates the FLIR high resolution 640×512 ISC1202 Indium Gallium Arsenide (InGaAs) 15-micron pitch focal plane array (FPA) and includes several advanced camera controls features.
-
Product
Intelligent Power Meter
TPU Series
-
The Yamasaki TPU Series Intelligent Power Meter is the latest design in Multiple Wavelength Optical Power Meter technology. The InGaAs detector is pre-calibrated for 850nm, 1300nm for Multimode and 1310nm, 1490nm, 1550nm and 1625nm for Singlemode wavelengths.
-
Product
Polychrometer (multichannel spectrometer)
-
It is a spectrometer that reduces the aberration of the optical system to the utmost limit because it measures effectively using multichannel detectors such as CCD, CMOS, InGaAs etc. Since the spatial resolution is high on the whole surface of the light receiving surface of the detector, it can be used for the following applications.
-
Product
2-Sensor SWIR Line-Scan Cameras
Wave Series
-
The Wave Series camera is a 2-sensor prism line scan camera capable of sensing Short Wave InfraRed (SWIR) light.The camera is based on Indium/Gallium /Arsenide (InGaAs) sensor technology and combined with JAI’s prism line scan technology, making it capable of delivering dual-band imaging in the SWIR light spectrum (900 – 1700 nm).
-
Product
InGaAs Camera with High Image Resolution
Cheetah Series
-
The Cheetah 640 series is based on a cooled, in-house developed InGaAs detector with a 640 x 512 pixel resolution. The Cheetah 640 camera with single-stage TE-cooled detector offers high frame rates of either 400 Hz, 800 Hz or 1700 Hz while the version with three-stage TE-cooled detector offers a frame rate of up to 110 Hz. The camera comes with a CameraLink interface.
-
Product
Photodiode
-
A high sensitivity receiver in a fiber pigtail coupled package, it includes a high speed InGaAs avalanche photodiode with a high gain TIA in a hermetically sealed coaxial package. It incorporates an LC/UPC pigtail and a flexible printed circuit (FPC). The signal GND and a receptacle are electrically isolated in this APD receiver.
-
Product
Cameras
-
Excelitas offers the broadest portfolio of scientific, industrial and specialized imaging camera systems on the market. Equipped with CCD, iCCD, CMOS, sCMOS or InGaAs sensors, our PCO imaging cameras have helped customers achieve successful and reliable measurements over three decades. We also design and manufacture a range of medium and long range thermal cameras covering the MWIR and LWIR wavebands which leverage our proven pedigree in designing and manufacturing high performance optical modules and cameras for demanding surveillance, targeting, naval and C-UAS applications.
-
Product
High-resolution, SWIR InGaAs camera
Wildcat+ 640 TE0 and WL Series
-
The Wildcat+ 640 TE0 and WL series is based upon a state-of-the-art uncooled InGaAs detector with 640×512 pixels and 20 μm pixel pitch. The WL version uses a special windowless sensor package for laser beam analysis applications. The camera offers superior, high-resolution SWIR imaging capabilities, comes in a versatile and industry-proven Wildcat camera package (GenICam compliant) and offers advanced on-board image processing.The Wildcat+ 640 TE0 and WL cameras output full frame images at 220 Hz via either a CameraLink or USB3 Vision interface.The Wildcat+ 640 TE0 and WL is suitable for semiconductor inspection, display inspection (mobile phone and TV), microscopy and laser beam analysis.Benefits & Features- Compact and industry-proven camera design- High resolution SWIR imaging- Advanced on-board image processing performance- GenICam complaint- Flexible optical mount and lens options
-
Product
Optical Spectrum Analyzer Module Specification
CA92001B
-
UCINSTRUMENTS CA92001B C band optical spectrum analyzer module is a spectral engine for Process Analytical Technology applications. The OSA module acts as a stand-alone spectral engine, imaging and measuring a wide range of vapors, liquids and solids through transmission and diffuse reflection in a rapid non-destructive process. Leveraging our proprietary Micro-Optic technology, UC INSTRUMENTS’ C band OSA module features the following characteristics: (1) compact; (2) light-weight; (3) low power consumption; and (4) wide wavelength coverage. These characteristics of UC INSTRUMENTS’ compact OSA engines are suitable for a variety of handheld, portable or bench-top OSA/spectrometer applications. Equipped with a state-of-the-art internal wavelength reference, the OSA module is capable of precisely measuring optical spectrum. Because it does not require an expensive InGaAs detector array, the compact OSA module is a cost-effective alternative to other grating-based OSA/spectrometer engines. The OSA communicates with a PC or an instrument motherboard via an USB interface. UCINSTRUMENTS’ OSA module platform can be installed or co-packaged into existing NIR OSA/spectrometers as a cost-efficient alternative to other scanning optical engines.
-
Product
SWIR and VIS-SWIR Cameras
-
A range of InGaAs based cameras offering “best in class” sensitivity in the region up to 1700nm.
-
Product
Avalanche Photodiodes
-
Excelitas offers Avalanche Photodiodes (APDs) on both Silicon (Si) and InGaAs materials. Si APDs cover the spectral range of 400 nm to 1100 nm and the InGaAs APDs cover 950 nm to 1550 nm. An Avalanche Photodiode (APD) provides higher sensitivity than a standard photodiode and is for extreme low-level light (LLL) detection and photon counting.
-
Product
SWIR and VIS-SWIR Cameras
-
A range of InGaAs based cameras offering “best in class” sensitivity in the region up to 1700nm.
-
Product
Digital VIS-SWIR Camera
OWL 1280
-
Using a 1280 x 1024 InGaAs sensor from SCD, the OwL 1280 offers visible extension from 0.6µm to 1.7µm to enable high sensitivity imaging. The 10µm x 10µm pixel pitch enables the highest resolution imaging. It will offer less than 28 electrons readout noise (rms) and with a high intra-scene dynamic range of 51dB, this enables simultaneous capture of bright & dark portions of a scene. Available with a 12 bit medium Camera Link digital output, the Owl 1280 will run from 10 to 60Hz. The camera features an on-board Automated Gain Control (AGC) which enables the best contrast image from low to bright light. The camera also has an on-board intelligent 3 point Non Uniform Correction (NUC) providing the highest quality images. As with all Raptor cameras, the Owl 1280 is ultra compact and rugged. The camera sensor temperature is stabilised to 15°C and the camera does not have a fan.
-
Product
PIN-TIA
-
The fiber-optic coaxial PIN-TIA receiver module is designed for SONET/SDH fiber-optical communicationnetworks, using reliable InGaAs PIN photodiode (PD) highly integrated with low noise transimpedence amplifier(TIA) to convert a long wavelength input optical signal into a differential (or single) output. It is a highly reliablemodule with excellent performance.
-
Product
High Performance Machine Vision Cameras
Goldeye
-
High-performance machine vision cameras with advanced features for demanding applications. QVGA and VGA Resolution. InGaAs sensors. Up to 344 fps. Spectral range 900 - 1700 nm (SWIR).
-
Product
Photodiodes & Arrays
-
Excelitas utilizes Silicon and InGaAs materials for our photodiodes to provide detection from 220 nm to 1700 nm. These devices are offered in a variety of sizes to meet customer sensitivity and speed requirements. Many different types of photodiodes are available to serve various unique applications.
-
Product
Spectrometers
-
BaySpec offers wide range of spectrometers from miniature handheld VIS – NIR - SWIR spectrometers, high-sensitivity UV – VIS – NIR – SWIR spectrometers, and CCD / InGaAs cameras. They are designed to meet real-world challenges for best-in-class performance, long-term reliability, compact size, and ultra-low power consumption. All these products provide fully customized OEM and ODM service to meet your spectroscopic needs.
-
Product
Pulse Characterization Sensors
-
Pulse Characterization Sensors provide the ability to see and measure the temporal characteristics of pulsed and CW laser beams. Ophir Fast Photodiode Detectors are designed to convert optical signals into electrical signals which are then measured with third-party instrumentation such as oscilloscopes and spectrum analyzers. Accessories are available to connect to IS6 integrating spheres or fiber optic cables. Attenuating filter accessories are also available to increase their dynamic range. Different models offer silicon, UV enhanced silicon and InGaAs PIN photodiodes, covering a combined spectral range of 193 nm to 1700 nm. Rise times range from 25 picoseconds to 3 nanoseconds. The fast rise times are achieved by an internal reverse bias voltage circuit. Power is supplied by internal batteries and/or an external power supply depending on the model. Detectors should be connected to a 50Ω impedance in order to maintain their nominal rise times. They can be connected to higher impedance loads, but this will result in a significant increase in the rise time. If higher output voltage is required, it is recommended to connect the detector to a trans-impedance amplifier with an Input impedance of 50Ω
-
Product
Photodiodes
Avalanche
-
Similar to photomultipliers, avalanche photodiodes are used to detect extremely weak light intensities. Si APDs are used in the wavelength range from 250 to 1100 nm, and InGaAs is used as semiconductor material in APDs for the wavelength range from 1100 to 1700 nm.
-
Product
Quad Optical Loss Test Set
KI27624-INGAAS
-
A Quad Optical Loss Test Set used to test power, insertion loss, continuity and faults on multimode and single mode fiber optic systems at 850 / 1300 nm & 1310 / 1550 nm. In a small package, it provides a powerful optical multi-meter style solution to improve test flexibility and productivity.
-
Product
Two-Way Optical Loss Test set
KI23422OLV-INGAAS
-
A Two-Way Optical Loss Test set (OLTS) that's perfect for medium to ultra high fiber count loss, length and optical return loss testing applications on single mode fiber at 1310 / 1550 nm. A pair of these compact instruments set new standards of productivity, accuracy and ease of use.
-
Product
Two-Way Optical Loss Test Set
KI23410OLF-INGAAS-APC
-
A Two-Way Optical Loss Test set (OLTS) that's perfect for medium to ultra high fiber count loss, length and optical return loss testing applications on single mode fiber with an APC connector at triple 1310 / 1550 / 1625 nm. A pair of these compact instruments set new standards of productivity, accuracy and ease of use. The 650 nm VFL is on a separate port.





























