Electron Spectroscopy for Chemical Analysis
determine the atomic composition of a surface.
-
Product
Electron Multipliers
-
Electron multipliers are mainly used as positive/negative ion detectors. They are also useful for detecting and measuring vacuum UV rays and soft X-rays. Hamamatsu electron multipliers have a high gain (multiplication factor) yet low dark current, allowingoperation in photon counting mode to detect and measure extremely small incoming particles and their energy. This means our Hamamatsu electron multipliers are ideal for electron spectroscopy and vacuum UV spectroscopy such as ESCA (electron spectroscopy for chemical analysis) and Auger electron spectroscopy as well as mass spectroscopy and field-ion microscopy.
-
Product
X-ray Photoelectron Spectroscopy Analysis (XPS Analysis)
-
Rocky Mountain Laboratories, Inc.
X-ray photoelectron spectroscopy (XPS Analysis) also called Electron Spectroscopy for Chemical Analysis (ESCA) is a chemical surface analysis method. XPS measures the chemical composition of the outermost 100 Å of a sample. Measurements can be made at greater depths by ion sputter etching to remove surface layers.
-
Product
XPS/ESCA Service
-
X-ray Photoelectron Spectroscopy (XPS Analysis), also known as Electron Spectroscopy for Chemical Analysis (ESCA), is used to determine quantitative atomic composition and chemistry. It is a surface analysis technique with a sampling volume that extends from the surface to a depth of approximately 50-70 Angstroms. Alternatively, XPS analysis can be utilized for X-ray Photoelectron Spectroscopy (XPS) or Electron Spectroscopy for Chemical Analysis (ESCA) from Evans Analytical Group (EAG).sputter depth profiling to characterize thin films by quantifying matrix-level elements as a function of depth.
-
Product
Imaging X-Ray Photoelectron Spectrometer
Kratos AXIS Nova
-
X-ray photoelectron spectroscopy (XPS), also known as electron spectroscopy for chemical analysis (ESCA), is a mature and widely used surface analysis technique for materials characterisation. XPS provides quantitative elemental and chemical state information from the upper most 10 nm of material. The The AXIS Nova photoelectron spectrometer can collect X-ray photoelectron spectra and images from any material that is stable under the ultra-high vacuum conditions required for the technique.
-
Product
RF Electronic Calibration Module (ECal), 300 KHz To 18 GHz, 4-ports
N4432D
Electronic Calibration Module
The Keysight N4432D is a precision 4-port ECal module that supports selection of Type-N and 3.5 mm connectors mixed up to 18 GHz. Select either female-female, male-male, or female-male connectors.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 7.5 GHz, 7-16, 2 Port
85098D
Electronic Calibration Module
The Keysight 85098D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 3.5 Mm, 2 Port
85093D
Electronic Calibration Module
The Keysight 85093D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, Type-N, 2 Port
85092D
Electronic Calibration Module
The Keysight 85092D RF electronic calibration (ECal) module makes calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Electronic Calibration Module (ECal), 67 GHz, 1.85 Mm, 2-Port
N4694D
Electronic Calibration Module
The Keysight N4694D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4694D is a precision 2-port ECal module that supports 1.85 mm connectors up to 67 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4694D is included for securing your ECal module and accessories.
-
Product
Electronic Calibration Module, DC To 6.5 GHz, 2-Port
N7551A
Electronic Calibration Module
Reduce your calibration time by half with a smaller, lighter 2-port module that supports 3.5 mm or type-N 50 Ω connectors
-
Product
Electronic Calibration Module (ECal), 26.5 GHz, 3.5 Mm, 2-port
N4691D
Electronic Calibration Module
The Keysight N4691D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4691D is a precision 2-port ECal module that supports 3.5 mm connectors up to 26.5 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4691D is included for securing your ECal module and accessories.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 7mm, 2 Port
85091D
Electronic Calibration Module
The Keysight 85091D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Electronic Calibration Module (ECal), 18 GHz, 7 Mm, 2-Port
N4696D
Electronic Calibration Module
The Keysight N4696D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy, and accurate. The N4696D is a precision 2-port ECal module that supports 7-mm connectors up to 18 GHz. The plastic storage case for the N4696D is included for securing your ECal module and accessories.
-
Product
Electronic Calibration Module, DC To 9 GHz, 2-Port
N7552A
Electronic Calibration Module
Reduce your calibration time by half with a smaller, lighter 2-port module that supports 3.5 mm or type-N 50 Ω connectors
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 26.5 GHz, 4-ports
N4433D
Electronic Calibration Module
The Keysight N4433D RF electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4433D is a precision 4-ports ECal module that supports selection of 3.5 mm connector and can be mixed up to 26.5 GHz. Select either female-female, male-male, or female-male connectors.
-
Product
Electronic Calibration Module (ECal), 50 GHz, 2.4 Mm, 2-port
N4693D
Electronic Calibration Module
The Keysight N4693D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy, and accurate. The N4693D is a precision 2-port ECal module that supports 2.4 mm connectors up to 50 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4693D is included for securing your ECal module and accessories.
-
Product
Electronic Calibration Module (ECal), 40 GHz, 2.92 Mm, 2-port
N4692D
Electronic Calibration Module
The Keysight N4692D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4692D is a precision 2-port ECal module that supports 2.92 mm connectors up to 40 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4692D is included for securing your ECal module and accessories.
-
Product
NVIDIA GPU And Intel® Xeon® AI Computing Platform For Autonomous Drive Applications
AVA-3510
Electronic Control Unit
The AVA-3510 Series is powered by an Intel® Xeon® E processor coupled with workstation-grade Intel®C246 chipset to support up to 64 GB ECC DDR4 memory. The system incorporates one 2.5" SSD 256G for easy installation as optional accessories for fast read/write performance.
-
Product
Multiport Electronic Calibration Module (ECal), DC To 20, 6-ports
N7564A
Electronic Calibration Module
A series of multiport ECal that cascade-able up to 36-ports which makes it possible to calibrate a wide frequency range from DC up to 20 GHz without making numerous connections during calibration process. Ideal for multiport measurement application with VNA in such as high-volume PA/FEM, massive MIMO antenna or high-speed digital interconnect test applications
-
Product
Multiport Electronic Calibration Module (ECal), DC To 9 GHz, 6-ports
N7562A
Electronic Calibration Module
A series of multiport ECal that cascade-able up to 36-ports which makes it possible to calibrate a wide frequency range from DC up to 9 GHz without making numerous connections during calibration process. Ideal for multiport measurement application with VNA in such as high-volume PA/FEM, massive MIMO antenna or high-speed digital interconnect test applications
-
Product
Electronic Calibration Module (ECal), DC-4 GHz, 2-Port
N7550A
Electronic Calibration Module
The N7550A is part of Keysight’s family of value-line electronic calibration (ECal) modules that makes calibration of vector network analyzers fast, easy and accurate. Cut your calibration down to half the time it normally takes using a traditional mechanical cal kit. Simply connect it to your instrument and the firmware does the rest. For greater precision and higher accuracy measurements consider the N44xx and N469x family of ECal products.
-
Product
Spectroscopy, Elemental & Isotope Analysis
-
Research, production and analytical laboratories worldwide rely on us for rapid, efficient qualitative and quantitative analysis. Our innovative instruments and user-friendly software serve a range of industrial, educational, environmental and health markets. We offer a comprehensive portfolio for the quantification and identification of trace elemental species at ppm to sub-ppt levels in addition to isotopes. We also provide a wide range of lab-based and handheld instruments employing analytical techniques including XRF, FTIR, NIR, Raman spectroscopy, IRMS, ICP-MS and more.
-
Product
Electronics Failure Analysis System
Sentris
-
Due to the continued decrease in integrated circuit feature size and supply voltages, detecting and locating the miniscule amount of heat generated by failure sites has become increasingly difficult. Sentris pinpoints low-level infrared thermal emissions from IC faults such as short circuits and leakage current.
-
Product
Spectroscopy
Vis-NIR Spectroscopy Lab Analyzers
-
Metrohm NIRS lab analyzers enable you to perform routine analysis quickly and with confidence – without requiring sample preparation or additional reagents and yielding results in less than a minute. Combining visible (Vis) and near-infrared (NIR) spectroscopy, these analyzers are capable of performing qualitative analysis of various materials and quantitative analysis of a number of physical and chemical parameters in one run.
-
Product
RF Electronic Calibration Module (ECal), DC To 13.5 GHz, 4-ports
N4431D
Electronic Calibration Module
The Keysight N4431D RF electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4431D is a precision 4-ports ECal module that supports multiple selection of connectors like Type-N, 3.5 mm, 7-16 and 4.3-10 connectors and can be mixed up to 13.5 GHz. Select either female-female, male-male, or female-male connectors.
-
Product
Chemical Calibration
-
Trescal provides full Chemical Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Chemical Calibration services can be delivered at your site or at our lab. Accreditations for our chemical calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Raman Spectroscopy
-
Raman spectroscopy is a form of vibrational spectroscopy, like infrared (IR) absorption, that provides detailed chemical and structural characterisation. The Raman technique has the benefit of being non-destructive and requiring no sample preparation.
-
Product
Autonomous Driving AI Decision Making ECU
ADM-AL30
Electronic Control Unit
ADM-AL30 is dedicated to Autonomous Driving Applications. Powered by Intel® 12th Gen Core i9/i7 CPU and the NVIDIA RTX 4000 SFF Ada GPU, this AI computing platform can process huge amounts of data and make crucial decisions for autonomous vehicles. Equipped with 2 x 10G Base-T and 8 x 1G Base-T1 automotive ethernet ports, as well as 8 x CAN FD and 4 x CAN 2.0 interfaces, it seamlessly integrates into any automotive ecosystem. Plus, its ISO 16750-2 and ISO 7637-2 ensure reliability and safety under the most demanding conditions.





























