Neulog
NeuLog logger sensors are the fruit of innovative thinking in technological training systems for hands-on education in the sciences, high-tech and industry for grade schools, high schools, universities, vocational schools, and after-school activities programs.
- info@neulog.com
- 850 St Paul Street
Rochester, NY 14605
United States of America
-
Product
Turbidity Logger Sensor
NUL-231
-
This sensor measures the reflected light that enters into a tube containing a solution. As solution turbidity is higher, more light is reflected and measured by the light sensor, located perpendicular to the light source.
-
Product
Ammonium Logger Sensor
NUL-240
-
The NeuLog ammonium sensor can be used to measure the concentration of ammonium ions (NH4+) in aqueous samples. It can be used to evaluate the degree of contamination of water due to the use of fertilizers.Ammonium measurements can also be very relevant to study the nitrogen cycle in general and to relate this cycle to plants and algae.
-
Product
Oxygen Logger Sensor
NUL-205
-
This sensor can be used to make measurements of the level of free oxygen in air or dissolved oxygen in water. The free oxygen in air mode is used to measure changes in oxygen levels during combustion or in reactions that produce oxygen (hydrogen peroxide decomposition). The dissolved and free oxygen modes are very useful in the study of photosynthesis.
-
Product
Light Logger Sesor
NUL-204
-
This sensor is very versatile with applications in many areas of the natural sciences. It can be used to study photosynthesis in biology, light-emitting chemical reactions in chemistry, the effect of changing voltage on a light-bulb's output in physics and more.
-
Product
Robotic and Computer Programming System
Sense
-
Sense is a robotic and computer programming system which allows users to explore, problem solve, and advance their computer programming abilities from just starting in visual block programming, to Python and C languages.
-
Product
Blood Pressure Logger Sensor
NUL-222
-
The sensor measures the pressure in the cuff wrapped on the tested person's arm.Heartbeats affect the blood pressure. That is the reason for the difference between the systolic and diastolic pressure of the tested person.
-
Product
Charge Logger Sensor
NUL-246
-
This sensor measures electrostatic charges. It can be seen as a highly sensitive electroscope indicating whether a charge is positive or negative. Other uses are: to explore the nature of static charge, to measure both charge and voltage, to measure charge by induction, quantify the charge on a capacitor or discover the charge distribution on a conducting sphere.
-
Product
Conductivity Logger Sensor
NUL-215
-
This logger sensor is based on a probe with two electrodes with known surface area and distance between them. A signal is supplied to the electrodes and by testing the signal behavior, the conductivity of the solution is calculated
-
Product
Heart Rate and Pulse Logger Sensor
NUL-208
-
This sensor can be used to monitor and compare pulse rates under various exercise and rest conditions. Additionally, it can show changes of blood volume/flow in the finger or ear lobe with time.The sensor has two modes of operation: measuring the BPM (Beats per Minute) of the heart rate or displaying the analog arbitrary value of the measured signal.
-
Product
Motion Logger Sensor
NUL-213
-
This sensor uses an ultrasonic transducer to transmit an ultrasonic wave and measure the time of the echo return. In this way, the sensor measures the distance to an article located against it.
-
Product
UVA Logger Sensor
NUL-232
-
There are different wavelengths of ultra violet light.The UVA wavelength range is 320-370 nm, which is 98% of the total UV radiation.The UVA radiation affects photoaging and also photochemical smog.The intensity of this light is measured in mW/m2 (milliwatt per square meter).
-
Product
UVB Logger Sensor
NUL-230
-
There are different wavelengths of ultra violet light. The UVB wavelength range is 280-320 nm, which is 2% of the total UV radiation. The UVB radiation affects the vitamin generation in the human body, the immune suppression, skin cancer and cataract. The intensity of this light is measured in mW/m2 (milliwatt per square meter).
-
Product
Digital Display Module
VIEW-200
-
The module automatically searches for the connected sensorsand displays one of them digitally. Scrolling for displaying thereading of another sensor is done by pressing the pushbuttonswitch on the display module.
-
Product
pH Logger Sensor
NUL-206
-
This sensor can be used to measure the static pH values of common liquids (water, milk, soft drinks, vinegar, etc.) as well as the changing values in titrations or experiments such as those looking at the effect of antacids.
-
Product
Sound Logger Sensor
NUL-212
-
This sensor has two modes of operation. In slow mode it can be used to measure sound-pressure level in decibels. In fast mode it can display waveforms of different sound sources such as tuning forks and wind-chimes so that period and frequency can be determined.