BAUR
The BAUR testing and measurement technology prevents damage to networks and systems, allows for accurate planning of investments for maintenance and locates faults as precisely and quickly as possible. For the reliability of your networks and systems.
- +43 5522 49410
- +43 5522 49413
- headoffice@baur.eu
- Raiffeisenstraße 8
Sulz, 6832
Austria
-
Product
VLF Testing and Diagnostics Unit
Frida TD
-
Cable testing and diagnostics with the BAUR frida TD. The portable and high performance high-voltage testing and diagnostics device is available in two different configurations: frida: Used for cable and cable sheath testing of medium-voltage cables and electrical equipment up to 20 kV. Another function is insulation testing on electrical equipment.frida TD: Expands the functional scope of frida with the tan delta diagnostics and Monitored Withstand Test (MWT) that combines the cable testing and dissipation factor measurement. This allows for an accurate and comprehensive assessment of the cable condition.* Cable testing and dissipation factor diagnostics in one device* Easy and quick test setup* Automatic testing and diagnostic sequences* Compact dimensions and lightweight
-
Product
Insulating Oil Testing
-
Insulating materials are the elixir of life of electrical equipment. These materials lose their insulating and cooling properties due to impuri ties and ageing. This damages equipment, causes failures and is consequently often accompanied by high costs. Precise and reliable measurement results.
-
Product
High-Voltage Test Device
PGK 260 HB
-
Cable testing and diagnostics with the BAUR PGK HB. There are hardly any other longer-lasting, more robust and cost-effective testing devices than the two-piece high-voltage test devices from the PGK HB series. They generate continuous adjustable test voltages with mains frequency or optionally DC with positive or negative polarity. The display instruments for current and voltage, the safety control unit and the regulating transformer for the voltage are integrated in the operating unit. *Testing of medium- and high-voltage cables * DC voltage testing of up to 260 kV output voltage with positive or negative polarity * AC voltage testing - up to 190 kV for switchgear, busbars and insulating elements * Easy-to-maintain 2-piece design
-
Product
Cable Fault Location System
BAUR Syscompact 2000 Portable
-
Cable fault location system Syscompact 2000 portable. The cable fault location system Syscompact 2000 portable is used for precise location of high-resistance and intermittent faults in low and medium voltage cables.* Fast and reliable* Precise, dependable cable fault location* High performance high voltage unit* Integrated proven cable fault pre-location methods
-
Product
Oil Breakdown Voltage Tester
DTA IL
-
Insulating oil testing with the BAUR DTA IL. The BAUR DTA Inline is a high performance and reliable oil tester for continuous testing of the breakdown strength of insulating oils during production (inline tests). The combination of extremely short switch-off times during breakdowns and the easy oil sample handling facilitate high quality statements and conclusions on the insulating oil quality.
-
Product
Cable Locator
CL 20
-
Cable fault location with the BAUR CL 20. The CL 20 cable locator comprising a transmitter and a receiver is used to determine the exact location of cables and metal pipes. The ability to determine laying depths of up to 4.5 m and to measure signal currents at the touch of a button allows you to obtain reliable information on the position of the cable within the shortest time.* Fast and exact location of position and laying depth of cables* Intuitive operation – no special measurement knowledge required* Lightweight and manageable
-
Product
Cable Test Van
Titron
-
Automatic cable test van. The BAUR titron is a new automatic cable test van designed for cable fault location and cable testing. The new generation of the high-performance cable test van is based on state-of-the-art technology and provides effi cient, safe and reliable cable fault location and cable testing.* New intuitive operational concept* Central, automatic system control* Top reliability and quality standard* Flexible in terms of technology and equipment
-
Product
VLF Test System
BAUR PHG 70 portable
-
Portable, high performance test generator with VLF truesinus technology. The BAUR PHG 70/80 portable VLF test systems are used for cable and cable sheath testing of medium-voltage cables of up to 50 kV and electrical equipment.* 3 voltage shapes in one device: VLF truesinus, VLF square wave and DC voltage* For medium-voltage cables of up to 50 kV operating voltage* Cable testing, fault conditioning, cable sheath testing
-
Product
High-Voltage Test Device
PGK 70/2.5 HB
-
Cable testing and diagnostics with the BAUR PGK HB. There are hardly any other longer-lasting, more robust and cost-effective testing devices than the two-piece high-voltage test devices from the PGK HB series. They generate continuous adjustable test voltages with mains frequency or optionally DC with positive or negative polarity. The display instruments for current and voltage, the safety control unit and the regulating transformer for the voltage are integrated in the operating unit.* Operation as DC or Ac testing device* Polarity of the DC voltage can be easily be reserved* Robust and durable
-
Product
Audio Frequency System
Locator Set / UL 30
-
Cable fault location with the BAUR Locator Set / UL 30. The audio frequency system Locator Set is used to exactly determine the alignment of cables and metal gas or water pipes. With various accessories, this system becomes a universal, indispensable device for power companies, industries, installation companies and water suppliers.* Output energy up to 50 VA* Automatic or manual impedance adjustment* Charging unit and rechargeable battery integrated; battery or mains operation* Continuous or cyclical output
-
Product
Surge Voltage Generator
SSG 3000
-
Cable fault location with the BAUR SSG 3000. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* high surge energy in each voltage range
-
Product
VLF Diagnostics System
PHG 80 TD
-
Cable testing and diagnostics with the BAUR PHG 80 TD. The combination of the PHG 80 programmable test generator with the BAUR dissipation factor measurement system produces the cable testing and diagnostics system PHG TD. It is operated via PC control. Dissipation factor measurement and diagnostic testing sequences can be programmed in the menu, after which the dissipation factor measured values are automatically determined in various voltage steps and a final evaluation is conducted.* Biggest dynamic range of tan delta measured values from 1 to 10-4 with a cable capacitance >10 nF to 20 uF* High resolution +/- 1x10-5 applicable even in new PE/XLPE cables* Insensitive against interferences due to complete mains separation* Lowest time required for assessing a medium-voltage cable (3-phase approx. 1 hour)
-
Product
High-Voltage Test Device
PGK 150 / 5 HB
-
Cable testing and diagnostics with the BAUR PGK H. There are hardly any other longer-lasting, more robust and cost-effective testing devices than the two-piece high-voltage test devices from the PGK HB series. They generate continuous adjustable test voltages with mains frequency or optionally DC with positive or negative polarity. The display instruments for current and voltage, the safety control unit and the regulating transformer for the voltage are integrated in the operating unit.* Testing of medium- and high-voltage cables* DC voltage testing of up to 150 kV output voltage with positive or negative polarity* AC voltage testing - up to 110 kV for switchgear, busbars and insulating elements* Easy-to-maintain 2-piece design
-
Product
Time Domain Reflectometer
IRG 2000
-
Cable fault location with the BAUR IRG 2000. The IRG 2000 impulse reflection measurement unit or time domain reflectometer is a handy, easy to carry device for single-phase cable fault pre-location. It is used in combination with a surge voltage generator on low-, medium- and high-voltage cables 0 - 65 km in length. It can also be used on live cables carrying voltage up to 400 V.* Easy and quick cable fault location* Light, compact and manageable* Main unit for the tried-and-tested pre-location method* Ideal for integration in measurement systems
-
Product
DC High-Voltage Test Device
PGK 80
-
Cable testing and diagnostics with the BAUR PGK 80. The portable, one-piece PGK 80 high-voltage test device for generating negative DC voltage up to 80 kV is primarily used for onsite testing of paper-insulated mass-impregnated cables in the medium-voltage network. The high voltage is generated through a high-voltage transformer with secondary voltage-multiplier. The internal operating frequency of 20 kHz enables the smallest of device dimensions.* Continuous adjustable output voltage* The voltage measurement is done directly at the high voltage output* Timer of 1-30 min* Sensitive current measurement for recording the smallest of insulation currents with 6-time range switch, decadal