Product
Fast Mobility Particle Sizer
3091
-
The Fast Mobility Particle Sizer 3091 (FMPS™) spectrometer measures particles in the range from 5.6 to 560 nm, offering a total of 32 channels of resolution (16 channels per decade). It uses an electrical mobility measurement technique similar to that used in our SMPS. However, instead of a CPC, the FMPS spectrometer uses multiple, low-noise electrometers for particle detection
-
Product
Aerosol Neutralizer
3077
-
Aerosol neutralization is an important component of aerosol science and engineering. Neutralizing aerosol particles can reduce electrostatic losses of particles within tubing or to other surfaces. Neutralization is also critical to gathering reliable particle size data when using a sizing instrument based on electrical mobility.
-
Product
Aerodynamic Particle Sizer (APS)
3321
-
The Aerodynamic Particle Sizer® 3321 (APS™ spectrometer) provides high-resolution, real-time aerodynamic measurements of particles from 0.5 to 20 microns. These unique particle sizers also measures light-scattering intensity in the equivalent optical size range of 0.37 to 20 microns. By providing paired data for each particle, the APS spectrometer opens up exciting new possibilities for those interested in studying the makeup of an aerosol.
-
Product
AEROTRAK™ Handheld Particle Counters
9306
-
The TSI AEROTRAK™ Handheld Particle Counters offer the most features and flexibility for customers interested in low cost and versatile particle contamination monitoring.
-
Product
Advanced Aerosol Neutralizer
3088
-
Aerosol neutralization is an important component of aerosol science and engineering. Neutralizing aerosol particles can reduce electrostatic losses of particles within tubing or to other surfaces. Neutralization is also critical to gathering reliable particle size data when using a sizing instrument based on electrical mobility.
-
Product
Aerosol Neutralizer
3077A
-
The Aerosol Neutralizer model 3077A is a general-purpose radioactive neutralizer suitable for use with highly-charged and/or highly concentrated aerosols. The Model 3077A can be used with flows up to 5 L/min. If your flow rate will always be significantly higher than this, consider model 3012 and/or 3012A. If your particles will not be highly-charged and/or highly concentrated, consider model 3077.
-
Product
Certifier Flow Analyzers
-
TSI Certifier™ Gas Flow Analyzers are multi-functional pneumatic test systems capable of measuring flow, pressure, temperature, and oxygen concentration. They are ideal for testing ventilators, anesthesia workstations, and any other respiratory medical device that produces flows or pressures.
-
Product
Engine Exhaust Particle Sizer
3090
-
TSI's Engine Exhaust Particle Sizer (EEPS™) 3090 spectrometer uses an array of sensitive electrometers, combined with three proprietary data inversion matrices, to provide real-time particle size data in 32 size channels (16 channels per decade). The data inversion matrices allow the researcher to optimize size distribution accuracy for specific particle types (soot, default and compact), and matrices can be applied at the time of measurement or in a post-processing environment. The EEPS spectrometer does not include any built-in sample dilution, giving the user maximum flexibility and independence with respect to sample conditioning. However, for measuring solid particles from engines, TSI now offers the Porous Tube Thermodiluter (PTT) 3098, a fully integrated sample conditioning solution for the EEPS spectrometer; the pair of them together is the Engine Exhaust Particle Measurement System (EEPMS) 3095.
-
Product
VELOCICALC Multi-Function Ventilation Meter
9565-X
-
The portable, handheld VELOCICALC® Multi-Function Ventilation Meter 9565-X features a menu-driven user interface for easy operation in your local language. On-screen prompts and step-by-step instructions guide the user through instrument setup, operation, and field calibration. The 9565-X also features an ergonomic, overmolded case design with probe holder and a keypad lockout to prevent tampering during unattended use. The 9565-X does not include a probe or pressure sensor.
-
Product
VELOCICALC Multi-Function Ventilation Meter
9565-A
-
The portable, handheld VELOCICALC® Multi-Function Ventilation Meter 9565-A features a menu-driven user interface for easy operation in your local language. On-screen prompts and step-by-step instructions guide the user through instrument setup, operation, and field calibration. The 9565-A also features an ergonomic, overmolded case design with probe holder and a keypad lockout to prevent tampering during unattended use. The 9565-A model includes the Articulated Probe 966 and is designed for use with a range of plug-in probes.
-
Product
Aerosol Neutralizer
3012A
-
The Aerosol Neutralizer Model 3012A is a radioactive neutralizer suitable for use with highly-charged and/or high concentration particles. It can handle flows up to 50 L/min. If your flow rate will always be near the lower end of this range and/or if your particles are not highly charged, consider the model 3012A.
-
Product
Alnor Velometer Thermal Anemometer
AVM430-A
-
The Alnor® Velometer® Thermal Anemometer AVM430-A is like having multiple meters for the price of one, yet it is still very simple to operate. The AVM430-A is the articulated probe version.
-
Product
Environmental Enclosure
8535
-
The custom designed, weatherproof DUSTTRAK™ Environmental Enclosure 8535 protects the DUSTTRAK II and DRX Aerosol Monitor Models 8530 and 8533. This environmental enclosure allows you to make the same accurate and precise measurements outdoors or in harsh industrial environments.
-
Product
Cascade Impactors
-
TSI’s suite of cascade impactors can collect particles with aerodynamic diameters (cutpoints) from 10 nm to 10 µm, in 3 to 13 different size fractions, and at flow rates of 2, 10, 30 or 100 L/min. The number of stages determines the size resolution of the collected samples, and consequently determines the level of detail of the data generated from the quantitative analysis of these collected samples.