Becker & Hickl GmbH
Becker & Hickl have introduced a proprietary time-correlated single-photon counting principle that made TCSPC more than 100 times faster than the existing devices. Moreover, bh introduced a multi-dimensional TCSPC process that records the photons not only versus the time in the signal period, but also versus other parameters, such as experiment time, wavelength, or spatial coordinates. The bh devices are designed to record multi-dimensional photon distributions, time-resolved images, sequences of photon distributions, or multi-dimensional time-tag data. The bh TCSPC products are complemented by bh picosecond diode lasers, detector modules, multi-spectral detector assemblies, and experiment control modules. Based on these components Becker & Hickl supply their own confocal fluorescence lifetime laser scanning microscope and FLIM upgrade kits for laser scanning microscopes of various manufacturers. Moreover, bh is supplier of TCSPC modules for commercial time-domain optical tomography instruments. bh market activities include currently 5 workshops around the world and distribution of more than 1200 pages of TCSPC literature.
- +49 (30) 212 80 02-0
- +49 (30) 212 80 02-13
- info@becker-hickl.com
- Nunsdorfer Ring 7-9
Berlin, 12277
Germany
-
Product
FLIM Upgrades for Nikon
A1 / C1 / C2
-
*bh FLIM Embedded in Nikon NIS-Elements Software*Two Fully Parallel TCSPC FLIM Channels*Compact bh Simple-Tau or Power-Tau System*Two HPM-100-40 GaAsP Hybrid Detectors*Excitation by bh ps Diode Lasers*Excellent Time Resolution: Electrical IRF Width 6.5 ps FWHM*Excellent Timing Stability*Time Channel Width Down to 813 fs*Megapixel FLIM, Up to 2048 x 2048 Pixels at 256 Time Channels*Detection Wavelength Range from 360 nm to 700 nm
-
Product
Instrument Software for SPC- and DPC Modules
SPCM
-
*Multifunctional 64 bit Data Acquisition Software*Recording of Multi-Dimensional TCSPC Results and Time-Tag Data*Control of Multi-Dimensional Recording Features*Configurable User Interface*Acquisition of Decay Curves, FCS, MCS Traces, FLIM and PLIM Images*Online Calculation and Display of FLIM, PLIM, FCS, PCH, MCS Traces and Fit of FCS Curves*Different Operation Modes Available*Measurement Control of Up to 4 Modules*Configurable for Different Instrument Configurations*Accumulation and Autosave Functions*Integrated Scanner Control*Saving, Loading and Conversion of Photon Distributions, Images and Time-Tag Data*Saving and Loading of Results and System Parameters*Integrated Control of Ti:Sa Lasers*Integrated Control of Motor Stages
-
Product
Instrument Software PMS Modules
PMS
-
*PMS Standard Software for Data Acquisition*Setting of Measurement Parameters*Control of Measurements for Up to 4 ModulesLoading and Saving of Measurement Data and Parameters*Display of Results as Curves or Bars
-
Product
Components for System Integration
-
Bh offers a wide range of accessories to improve your photon counting experiment such as experimental control modules, optomechanics or implantable fiber probes for in-vivo applications. For PMTs and MCPs we offer different preamplifiers and a variety of routing devices for multi-detector operation. For a perfect SYNC signal, trigger modules and a SYG are available.
-
Product
Fiber-Based TCSPC System
-
*Hybrid Fiber System With Implantable Fiber Tip*Tip Removable from Fiber System*Seperate Excitation and Detection Fibers*Extremly Low Background Fluorescence*One or Two bh ps Diode Laser (BDS-SM or BDL-SMN Series)*High-Efficiency HPM-100-40 or -50 Hybrid Detector*Optional: Multi-Wavelength Detector
-
Product
Laser
BDS-MM Series
-
*Pulse Width Down to 60 ps*Repetition Rate 20 MHz / 50 MHz*Free Beam or Fiber Output*Optical Power Up to 40 mW*All Electronics Integrated*No External Driver Unit*Simple +12 V Supply*40 mm x 70 mm x 120 mm
-
Product
Laser Scanning FLIM Microscopes
-
DCS-120 laser scanner: Compact - Flexible - Precise. As technology leader in equipment and techniques for single photon counting, Becker & Hickl offers the DCS-120 systems that are complete laser scanning microscopes for fluorescence lifetime imaging (FLIM) since 2007. The systems use bh’s multi-dimensional TCSPC FLIM technology in combination with fast laser scanning and confocal detection or multi-photon excitation.
-
Product
Laser
BDL-SMN Series
-
*Pulse Width Down to 40 ps*Repetition Rate 20 MHz / 50 MHz / 80 MHz / CW (Switchable)*Free Beam Output or Single-Mode Fiber Coupling*Beam Profile Correction Optics*All Electronics Integrated*No External Driver Unit*Simple +12 V Supply*Fast On / Off / Multiplexing Capability*Synchronisation Input
-
Product
Fluorescence Lifetime Systems
-
TCSPC, short for time-correlated single photon counting, refers to a powerful analysis method used especially in life sciences and fundamental physics. This technique is used to perform hyper-accurate fluorescence and phosphorescence lifetime measurements. As technology leader in equipment for multidimensional single photon counting, Becker & Hickl has been offering a wide range of high-efficiency TCSPC systems since 1993.
-
Product
Analysis Software for FLIM, PLIM
SPCImage
-
*Analysis of Single-Decay, FLIM and PLIM Data*Analysis by Iterative Convolution and Fit Procedure or by First Moment of Photon Distribution*Calculations of Decay Parameters and Lifetimes by Various Decay Models*Calculation of FRET Efficiencies*Display of Lifetime and FRET Images*Display of Lifetimes, Amplitudes, Intensities or Ratios*Export of Lifetime Data and Images