Teledyne Advanced Pollution Instrumentation
Teledyne API (TAPI) designs and builds precision air quality and industrial gas monitoring instrumentation at our factory located in San Diego, California, USA. Our products are used worldwide in ambient air quality monitoring systems (AQMS), continuous emissions monitoring systems (CEMS), and industrial process applications.
- (858) 657-9800
- (858) 657-9818
- api-sales@teledyne.com
- 9970 Carroll Canyon Road
CA, San Diego 92131
United States of America
-
product
Maintenance & Service
Teledyne Advanced Pollution Instrumentation
Get peace of mind with preventative maintenance procedures that when performed regularly, will help to ensure your analyzer continues to operate accurately and reliably over its lifetime.Proactive maintenance at scheduled intervals is key to your equipment’s accuracy and longevity. Pre-planned, periodic maintenance provides cost control with complete trust that your equipment is achieving:Consistent, accurate resultsExtended instrument lifeEliminate premature replacement of equipment.The best performance possibleEquipment downtime is decreased and the number of major repairs are reduce
-
product
Dissolved Ozone Instruments
Teledyne Advanced Pollution Instrumentation
For measuring dissolved ozone concentrations in water a microprocessor controlled instrument can be used for automatic and continuous measurement by means of an disinfectant sensor. All of our instruments are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring.
-
product
UV Absorption O3 Analyzer
Model T400
Teledyne Advanced Pollution Instrumentation
The Model T400 UV Absorption analyzer uses a system based on the Beer-Lambert law for measuring low ranges of ozone in ambient air.A 254 nm UV light signal is passed through the sample cell where it is absorbed in proportion to the amount of ozone present. Periodically, a switching valve alternates measurement between the sample stream and a sample that has been scrubbed of ozone. The result is a true, stable ozone measurement.
-
product
Trace-level, Photolytic, True NO2/NO/NOx Analyzer
Model T200UP
Teledyne Advanced Pollution Instrumentation
The Model T200UP provides trace level measurements of NO and NO2 using our Model T200U NOx analyzer combined with a patented high efficiency photolytic converter. Even low temperature molybdenum converters transform other nitrogen-containing compounds such as HNO3, PAN, etc. to a considerable extent. Simultaneous measurements of NO2 performed with molybdenum and photolytic converters have shown significantly different results in the presence of such compounds.
-
product
Gas Filter Correlation CO Analyzer
Model N300
Teledyne Advanced Pollution Instrumentation
The Model N300 is a microprocessor-controlled analyzer based on the Beer-Lambert law that is used to determine the concentration of carbon monoxide (CO) in a sample gas.The N300 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb Infrared (IR) light. The analyzer passes the IR light beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.
-
product
Trace Level Portable Gas Calibrator
Model T750U
Teledyne Advanced Pollution Instrumentation
The Model T750U is a portable, microprocessor based calibrator for precision trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero calibrations. The T750U is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field.
-
product
CAPS Trace-Level NO2 Analyzer
Model T500U
Teledyne Advanced Pollution Instrumentation
The T500U CAPS NO2 Analyzer represents the next generation of criteria pollutant monitoring technology for the direct measurement of Nitrogen Dioxide (NO2) in air. The instrument utilizes a patented Cavity Attenuated Phase Shift (CAPS) technique to provide an extremely sensitive, fast and accurate NO2 measurement in a cost effective and low maintenance instrument package.The T500U provides a direct NO2 measurement, eliminating the need for catalytic conversion or reagents which introduce measurement artifacts inherent in traditional heated metal converter based chemiluminescense instruments. The CAPS measurement approach also reduces maintenance items, and removes the need for hazardous materials and high temperature scrubbers within the instrument. The T500U has an expected maintenance interval of one year under typical ambient monitoring conditions.
-
product
Chemiluminescence NO/NO2/NOX Analyzer
Model T200
Teledyne Advanced Pollution Instrumentation
The Model T200 NO/NO2/NOx analyzer uses the proven chemiluminescence detection principle, coupled with state-of-the-art electronics to allow accurate and dependable low level measurements for use as an ambient analyzer or dilution CEMS monitor.A unique AutoZero feature provides superb stability by continuously correcting for zero drift, while advanced Adaptive Filtering allows the analyzer to optimize performance under changing conditions. The Model T200 includes a permeation inlet dryer for ozone generation to provide excellent reliability with no periodic replacement required. A catalytic exhaust ozone scrubber is standard for maximum safety and pump life.
-
product
Ozonator Controller
SCI-552
Teledyne Advanced Pollution Instrumentation
The SCI-552 is a system controller for ozone delivery systems that provides electronic control interfaces for a number of typical system components, including: ozone generators, EV valves, mass flow controllers, back-pressure controllers, Teledyne API 452 ozone sensors, Teledyne API 470 dissolved ozone sensors, and a water chiller.
-
product
PM Mass Monitor
Model T640
Teledyne Advanced Pollution Instrumentation
The Model T640 PM Mass Monitor is the next breakthrough in ambient particulate monitors. The T640 delivers 1-min or better time resolution with exceptional sensitivity and precision. The instrument is very low maintenance and requires no sample media for minimal cost of operation.
-
product
Mid-Range Chemiluminescence NO/NO2/NOX Analyzer
Model T200M
Teledyne Advanced Pollution Instrumentation
The Model T200M combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. The option of either a molybdenum converter or a high-efficiency stainless steel thermal NO2 converter allows the T200M to be used in a variety of extractive CEM systems, from gas turbines to coal-fired boilers.
-
product
Portable Trace-Level O3 Calibrator
Model T753U
Teledyne Advanced Pollution Instrumentation
The Model T753U is a portable, microprocessor based precision Calibrator for Ozone gas instruments and sensors. Using a sophisticated Ozone generation system, combined with a sensitive photometer and pneumatic design, the T753U produces stable and reliable concentrations of Ozone in a convenient and rugged package based on our popular T750U Portable Multigas Calibrator platform. The T753U is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field for virtually any application. An internal zero air option extends the T753U's capabilities to also provide a clean and dry source of zero air, eliminating the need for a separate source of zero air. The internal zero air source module contains a software driven electronic inlet valve manifold allowing the calibrator to automatically switch between internal and external zero air sources depending on the application needs.
-
product
Process Ozone Monitor
Model 454
Teledyne Advanced Pollution Instrumentation
The Model 454 is a microprocessor based gas monitor for measuring mid to high concentrations of ozone in oxygen or air.Available in a standard DIN panel mount configuration with a 4-digit LED display, the compact design provides ease of mounting and installation.
-
product
Zero Air System
Model T701
Teledyne Advanced Pollution Instrumentation
The T701 adds Modbus TCP/IP connectivity to the proven reliability and performance of our zero air systems. This allows remote monitoring of key instrument functions including dewpoint status, scrubber temperature, box temperature, and output pressure. Additionally, this digital access provides the ability to remotely disable the internal pump, allowing longer service intervals and less power consumption. The user can also remotely start instrument warm-up prior to arrival at the site.The T701 is a fully self-contained source of clean, dry air for dilution calibrators. It can also be used to create purge air for permeation tube ovens or burner air for FID analyzers. The T701 includes a dewpoint sensor, an oil and diaphragm-free pump, and scrubbers to remove SO2, NO, NO2, O3, H2S, and NH3. Optional high performance scrubbers are available to remove CO and Hydrocarbons.
-
product
Trace-Level Chemiluminescence NO/NO2/NOx Analyzer
Model T200U
Teledyne Advanced Pollution Instrumentation
The Model T200U Trace-level NO/NO2/NOx analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven chemiluminescence principle and is designed to allow ultra-sensitive measurements with a lower detectable limit of 50 ppt while still meeting the requirements for use as a US EPA compliance analyzer.The Model T200U combines a gold plated reaction cell with an enhanced performance pump, special low noise photomultiplier tube, and unique signal conditioning to provide exceptional sensitivity. In addition, a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer.